Eltra CHS 580 Hydrogen Analyzer is the ideal analyzer for the simultaneous determination of carbon, hydrogen and sulfur in organic samples. Thanks to sample weights of 500 mg and more, even inhomogeneous materials can be reliably analyzed.
The temperature of the powerful horizontal resistance furnace with ceramic tube can be set in steps from 1 °C to a maximum of 1,550 °C. The analyzer can be equipped with up to three independent infrared cells according to the user‘s requirements, allowing for a great variety of applications.
Eltra CHS 580 Hydrogen Analyzer Advantages
- Simultaneous carbon, sulfur and hydrogen determination with minimal sample preparation
- Wide range of organic materials can be analyzed
- Rapid, precise, accurate and reliable element determination
- Resistance furnace can be set up to 1550 °c in steps of 1 °c
- Customized infrared cells provide wide, dynamic measuring range
- Due to gold ir path, increased cell live time for analysis of halogen or acid containing samples
- Powerful software (multilingual, customized display, export of results)
- Single and multi-point calibration
- Low maintenance
- Robust design allows usage in production control and laboratory
Application
Coal, Coke, Oil, Plant Materials, Rubber, Soot, Tobacco, Waste, etc
Eltra CHS 580 Hydrogen Analyzer Specification
Measured elements | carbon, hydrogen, sulfur |
Samples | organic |
Furnace alignment | horizontal |
Sample carrier | ceramic boats |
Field of application | agriculture, biology, chemistry / |
plastics, coal / power plant, | |
construction materials, environment / | |
recycling, medicine / | |
pharmaceuticals | |
Furnace | resistance furnace (ceramic tube), |
adjustable up to 1550 °C (steps of 1 | |
°C) | |
Detection method | solid state infrared absorption |
Number of IR cells | 1 -3 |
Material of IR path | gold |
Typical analysis time | 60 – 180 s |
Chemicals required | magnesium perchlorate, sodium |
hydroxide | |
Gas required | oxygen 99.5 % pure (2 – 4 bar / 30 – |
60 psi) | |
Power requirements | 230 V, 50/60 Hz max. heat up |
current 2000 W | |
Dimensions (W x H x D) | 55 x 80 x 60 cm |
Weight | ~ 70 kg |
Required equipment | balance (resolution 0.0001g), |
monitor, PC | |
Optional accessories | TIC module, voltage stabilizer 5 KVA |
Download Data Sheet: Carbon / Sulfur / Hydrogen Analyzer CHS-580