Determination of surface carbon is a special requirement for quality control in the metal producing and metal working industry. ELTRA’s SurfaceC-800 analyzer is designed for the precise determination of surface carbon in numerous kinds of solid samples from trace level up to 1000 µg/cm2 .
The ELTRA SurfaceC-800 is equipped with a resistance furnace with quartz tube for sample oxidation and can provide temperatures up to 1000 °C. The temperature of the SurfaceC-800 can be set up in steps of 1 °C. As common carrier gas in the SurfaceC-800 oxygen is used.
The detection system of ELTRA’s SurfaceC-800 is very sensitive, reliable and guarantees a long lifetime. It can be customized according to the user’s requirements. It is possible to combine two infrared cells independently to allow for highly precise measurement of surface carbon from trace level up to large amounts
Advantages
- Surface carbon determination with minimal sample preparation
- Large sized samples can be measured (up to 32 x 145 mm)
- Rapid, precise, accurate and reliable element determination
- Wide range of materials can be analyzed
- resistance furnace temperature can be set up to 1000 °c in steps of 1 °c
- Customized infrared cells provide wide, dynamic measuring range
- Optional gold ir path for analysis of halogen or acid containing samples
- Calibration with standard materials or gas dose
- Special sample sluice for reduction of atmospheric blank
- Powerful software (multilingual, customized display, export of results)
- Single and multi-point calibration
- Electronic gas flow control low maintenance
- Robust design allows usage in production control and laboratory
Application
Aluminum, Ceramics, Metals, Surface Carbon On Steel
Another Article: |
Specification
Measured elements | carbon |
Samples | inorganic |
Furnace alignment | horizontal |
Sample carrier | quartz boats |
Field of application | ceramics, steel / metallurgy |
Furnace | resistance furnace with quartz tube, |
adjustable up to 1000 °C | |
Maximum sample size | 32 x 145 mm |
Detection method | solid state infrared absorption |
Number of IR cells | 01-Feb |
Material of IR path | aluminum (optional gold) |
Typical analysis time | 60 – 90 s |
Chemicals required | magnesium perchlorate, sodium |
hydroxide | |
Gas required | oxygen 99.5 % pure (2 – 4 bar / 30 – |
60 psi) | |
Power requirements | 230 V, 50/60 Hz, max. 10 A, 2300 W |
Dimensions (W x H x D) | 55 x 80 x 60 cm |
Weight | ~ 65 kg |
Required equipment | balance (resolution 0.0001g), |
monitor, PC | |
Optional accessories | voltage stabilizer 5 KVA |
Ref: eltra.com
Contact us : sales@wmablog.com or visit to our E-Commerce
Download Data Sheet: Surface Carbon Analyzer SurfaceC-800