Pulsar Non-contacting Ultrasonic Level Control and Flow Measurement Ultra 4 offers the sophistication and advanced features of the rest of the Ultra range in a compact, cost effective package and useful new features that make it even easier to set up and fine-tune. Offering as the name suggests, four alarm or control relays (3 X SPCO isolated and 1 x SPNO solid state) and a multi-functional display while loosing none of the easy set up and configuration that has made the Ultra range the natural choice for non-contacting measurement world-wide.
Like the rest of Pulsar’s ‘transducer plus controller’ ranges, Ultra 4 is compatiable with both dB ultrasonic and dBR radar transducers. Ultra 4 can be wither wall or fasica mounted and includes HART, Profibus and Modbus digital communications options and the convenience of on-board micro SD card slot for extended data logging.
Like the rest of the Ultra range, Ultra 4 also offers built in volume calculations based on standard tank shapes as well as advanced pump control and open channel flow measurement functions.
Specifications
Physical
Mounting option: |
Standard Wall Mount: |
Fascia Mount: |
Controller body dimensions: |
150 x 130 x 63.5mm (5.9 x 5.1 x 2.5”) |
160 x 180 x 63mm (6.3 x 7.07 x 2.5”) |
Weight: |
Nominal 700g |
Nominal 700g |
Enclosure Material/Description: |
10 cable entries. 1 x M16, 5 x M20 underside, 4 x PG11 at rear |
Polycarbonate, flame resistant to UL94-V0 |
Cable Entry Detail: |
3 x M20 glands |
|
Transducer Cable Extensions: |
3-core Screened |
|
Maximum Separation: |
1000m, 500m for dBR16 and dBR8 |
|
Environmental
IP Rating: |
IP67/NEMA 4X |
Max. and Min. Temperature (electronics): |
-20 ºC to +45 ºC (-4 ºF to +113 ºF) |
Flammable atmosphere approval: |
Safe area: compatible with approved dB transducers |
UV Rating: |
UL746C F1 |
CE Approval: |
See EU Declaration of Conformity |
UL Approval: |
UL61010-1 pending |
Performance
Accuracy: |
0.25% of the measured range or 6mm (whichever is greater) +/- 2mm for dBR16 mmWAVE RADAR |
Resolution: |
0.1% of the measured range or 2mm (whichever is greater) |
Max Range: |
Depending upon transducer, from 125mm to 40m (0.41-130ft). 50m on modified Ultra 3 and Ultra 5. (0 to 2.425m (0 – 7.95ft) dBMACH3 for open channel flow) |
Min Range: |
Dependent on application and transducer (maximum 40m dB40) |
Echo Processing: |
Dependent on application and transducer (minimum zero dBMACH 3) |
Rate Response: |
Fully Adjustable |
Echo Processing
Description: |
DATEM (Digital Adaptive Tracking of Echo Movement) |
Technologies: |
Ultrasonic and FMCW RADAR |
Outputs
Analogue Output: |
Isolated (floating output (to 150V) of 4-20 mA or 0-20 mA into 1KΩ (user programmable and adjustable) |
Digital Output: |
Half Duplex RS232 |
Volt Free Contacts, Number and Rating : |
3 x SPCO isolated relays, rated at 5A at 250V AC and 1 Solid state SPNO isolated relay, rated 30V at 100mA, suitable for pulse counter applications |
Display: |
Monochrome graphical dot-matrix, 160 x 240 pixels. Fully programmable display options with integral keypad with menu navigation keys. Program/run/test mode indicators |
Programming
On-Board Programming: |
Via Integral Keypad |
PC Programming: |
Via Integral RJ11 port on unit, or via SD Card slot |
Programming Security: |
Via passcode (user selectable and adjustable) |
Promgrammed storage: |
Via non-volatile memory |
Data Logging and Removable Storage: |
Via Micro SD card slot or internal 10-day totaliser logs (flow only) |
SD Card Memory (included): |
8GB |
Supply
Power Supply: |
100 to 240V AC 50/60 Hz. DC 10-28 V |
Power Consumption: |
AC = 20VA MAX, DC = 10W max |
Fuses, mains: |
1A ‘T’ 20mm ceramic 1500A breaking |
Fuses, transducer: |
100mA barrier type, 4000A breaking |
Communications (optional)
Modbus RTU/ASCII: |
Isolated RS485 |
Profibus DPV1: |
Isolated RS485 |
HART 7: |
Isolated 4-20mA |
DNP3/WITS: |
Gateway interface (pending) |
Download Datasheet: Ultra 4 Pulsar Non-contacting Ultrasonic Level Control and Flow Measurement
Reference : pulsar-pm.com