Description
The TE KPSI 705 is a submersible hydrostatic level transducer specifically designed to meet the adverse environments encountered in wastewater applications. This suitably-sized transducer features a wide sensing area comprised of a PTFE coated elastomeric diaphragm for reliable operation in highly viscous or slurry environments.
All KPSI Transducers utilize a highly accurate pressure sensor assembly. The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel or titanium.
The attached polyurethane or ETFE electrical cable are custom manufactured to specifications and includes para-aramid synthetic fiber members to prevent errors due to cable elongation, and a unique water block feature that self-seals in the event of accidental cuts to the cable.
Each vented reference transducer is shipped with our latest SuperDry Vent Filter that prevents moisture from entering the vent tube for at least one year without maintenance, even in the most humid environment.
Features
- Custom polyurethane or ETFE cable lengths
- Welded 316SS or titanium body
- Custom level ranges up to 115 ft. (35 m) H2O
- PTFE coasted elastomeric diaphragm
- Optional lifetime lightning protection
- Available molded cable seal
Applications
- Lift stations
- Wastewater
- Slurry Tanks
- Pump control
Specification
Parameter | Comment | |
Level Ranges | ||
Full-scale level ranges (Intermediate level ranges are available) | 6 thru 115 ft. H20 (2 thru 35 m H20) 10 thru 115 ft. H20 (3 thru 35 m H20) | Vented Gage Reference Sealed Gage Reference |
Proof pressure | 1.5 x FS | |
Burst pressure | 2.0 x FS | |
Static Performance | ||
Static Accuracy (combined effects of non-linearity, hysteresis and repeatability, best fit straight-line method) | ±0.25% FSO | BFSL method |
Resolution | ±0.0001% FS | |
Electrical | ||
Excitation | 9-28V – VDC output 9-28V – mA output 15-28V – VDC output 10-28V – VDC output | 0-5V, 0-2.5V, 0-4V 4-20 0-10V 1.5-7.5V |
Input current | 20 mA max 3.5 mA max | For mA output For VDC output |
Output | 4-20mA, 0-5 VDC, 0-2.5VDC, 0-4VDC, 0-10VDC, 1.5-7.5VDC | |
Zero Offset | Rezero after installation for optimum accuracy. Span is not affected (See application note on website) | |
Output Impedance | See loop diagram for mA output 20 ohm for VDC output | |
Insulation Resistance | 100 mega-ohm at 50 VDC | |
Circuit Protection | Polarity, surge/shorted output | |
Physical | ||
Approximate Weight | 0.5 lbs. (227 g) transducer 0.05 lbs./ft. (79 g/m) cable | |
Cable jacket material | Polyurethane (standard) ETFE (optional) | |
Cable pull strength | 200 lbs. (90 kg) | |
Cable number of conductors | 4 | |
Cable conductor size | 22 AWG | |
Cable seal | Molded polyurethane FKM Gland | For polyurethane cable For ETFE cable |
Download Datasheet: TE Connectivity KPSI 705 Submersible Level Transducer
Another Article:
- TE KPSI 710 Hydrostatic Level Transducer
- TE KPSI 750 Submersible Hydrostatic Level Transducer
- TE KPSI 745 Hydrostatic Level Transducer
- TE Submersible Level Transducer KPSI 320
For further info please contact us, marketing@wmablog.com