Bamo Level Measuring Transducer MAXIMAT SHR CS

Level Measuring Transducer MAXIMAT SHR CS
Level Measuring Transducer MAXIMAT SHR CS

Bamo Measures Sas has been founded in 1978. Its capital is now 400 000 Euros. Since the beginning, the company has undergone a rapid development centring on industrial pH-meters and conductivity meters. Bamo is now well-known as a leader on the French market.

Since 1990, new developments in the Level Measure have given a new spring in the export. To its own production range, the company holds numerous agencies of foreign companies in Europe and all over the world. So we are offering a complete line with always the best possible service.

Bamo is a company that comes from France. This company selling some product. The product of Bamo such as pH and ORP; Chlorine, disinfection; Data processors; Conductivity; Water hardness; Turbidity; Oxygen; Level; Temperature; Flow; Pressure; Plastic valves; Metal valves.

Level Measuring Transducer MAXIMAT SHR CS

This power supply and alarm signal relay SHR CS (DIN rail mounting) is specially designed for the new MAXIMAT leakage and overfill transmitters and liquid filling of pipes sensors CAPSYTRON SFL. It is useful with the previous range MAXIMAT SU and VK. It assures a continuous survey of the measurement loop, a LED indicates the circuit status. The alarm signal drives 2 output relays to control 2 separates systems such as a horn and a flashing light.

Features

  • Designed for overfill and leakage sensors
    MAXIMAT®C,
    MAXIMAT®VK,
    MAXIMAT®LW,
    CAPSYTRON SFL
  • DIBT Approval

Another Article:

Specification

Supply power: 230 V ± 10%, 50/60 Hz or 24 V DC ± 10%
Power consumption: about 3 VA / 3 W
Ambient temperature: -20 to +60° C
Housing: 22.5 x 75 x 110 mm, IP 40 for standard rail per DIN EN 50 022 (35 x 7.5 mm top-hat rail)
Terminals: Screw terminals, IP 20 maximum wire cross-section 2.5 mm2
Relay outputs: 2 floating changeover contacts, maximum 250 V (50/60 Hz) 3 A, or 115 V DC, 0.5 A
Minimum load: 10 mA at 5V DC
Indicators: green LED operation
green LED relay pulled in
red LED overfill/leakage alarm
red LED interrupted circuit
red LED short-circuit
Delay time: release delay adjustable from 0.3 to 3 sec,
Measuring circuit: 12 V DC maximum, short circuit 110 mA maximum
inductance <5 mH maximum
capacitance < 0.5 μF maximum
Measuring cable 300 m maximum, wire cross-section 0.5 mm2 minimum
CE mark: in accordance with low-voltage directive (73/23/EWG), EMC directive (89/336/CEE) and standards EN 50 082-2: 1995, EN 55 011 (class A) 1998, EN 610010-1 1993
DIBT approval: Z-65.11-122, Z-65.13-265, Z-65.13-294, Z-65.40-201 and Z-65.40-272 for leakage and overfill detection.

Download Data Sheet: Level Measuring Transducer MAXIMAT SHR CS

Ref: bamo.eu