Sonic BL-550 Ultrasonic Boundary Level monitoring for the sewage tank, deposit tanks, liquid isolation tank, solid/liquid separator tank.
Feature
- Faster response to a change in boundary
- Continuous measurement without disturbance
- Less mechanical parts, easy maintenance
- Real-time monitoring with images
Another Article: |
Application
- Boundary level monitoring at the water treatment plant
- Sludge monitoring, control and management
- Carryover protection
- Iron and steel, automobile, chemical, thermal power plant, pulp, and food
- Settling tank and separation tank drain control
- Water and sewage
- First precipitator, concentrator, last precipitator
Specification
Converter
Model: | BL-550 Converter |
Measuring method: | Ultrasonic pulse-echo technique |
Measuring range: | 0 (+dead band)?10m, dead band = 30cm |
Accuracy: | ± 1cm (in-house evaluation) |
System control: | Controlled by CPU |
Detection period: | Once or twice per second |
Display: | LCD Display (16 x 2) |
Output: | Boundary level, 4-20mA analog output |
Boundary alarming, (upper/lower limit relay type output) | |
Contact output once the sensor signal are missed | |
Data for images monitoring | |
Input: | 4-20mA analog input, as position correction information |
Operating condition: | Temperature -10 ? +40ºC (no freezing) |
Humidity 20 ? 80% (no condensation) | |
Power supply : | AC100V, 115V, 220V,50/60Hz |
Power dissipation: | 10VA |
Dimensions: | 304W x 320H x 135D (except convex part) |
Housing material: | Stainless (SUS304) |
Protection grade: | IP44 |
Weight: | 8.2 Kg |
Sensor
Model: | T-129 type transmitter/receiver |
Structure: | Resin mold, water-proof (include bracket and cleaning nozzle) |
Frequency: | 200kHz |
Weight: | 7 kg |
Ambient temperature: | -5 ? +60ºC |
Cable length: | 14m (2 core shield flexible cable) |
Catalog : BL-550Boundary Level sensor