ABB FCB100 Coriolis Mass Flow Meter

Description

ABB FCB100 Mass Flowmeters series of compact system integration flowmeters feature low-pressure drop, high flow capacity, high-speed RS485 Modbus communication, and 2 digital outputs.

With no up or downstream piping requirements, the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.

ABB FCB100 Mass Flowmeters delivers:

  • Superior accuracy and speed for filling applications
  • Full parameter access with up to 115 kBaud
  • Aluminum housing or all stainless steel solution
  • DTM-based diagnostic and operability functions

The sensor delivers:

  • Multivariable measurement of mass flow, density, and temperature in one device
  • Low-pressure drop saves 25 % on pump energy costs compared to other brands
  • Wide measurement span in a single meter

FCB150 adds:

  • DensiMass: High accuracy concentration measurement, water cut, and net-oil computing as well as net-mass and net-volume measurement
  • FillMass: Filling application software with integrated counter, over-and-underfill correction, and contact output for valve control

ABB FCB100 Mass Flowmeters General specifications:

  • Nominal sizes/measuring ranges
    •  DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
    •  DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
    •  DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
    • DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
    • DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
    • DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h)
  • Ex approvals : ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2
  • Wetted materials :  1.4404 / 1.4435 (316L) or Hastelloy C
  • Accuracy for liquids
    • FCB130
      •  Mass and volume: 0.4 % o. r. / 0.25 % o. r.
      • Density: 10 g/l
    • FCB150
      •  Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
      •  Density: 2 g/l or 1 g/l
  • Measuring medium temperature
    FCB130
    –  -50 to 160 °C (-58 to 320 °F)
    FCB150
    –  -50 to 205 °C (-58 to 400 °F)
  • Outputs
    – 2 digital out (pulse, frequency, contact)
    – Modbus
  • Power supply
    – 11 to 30 V DC

Reference: new.abb.com