Alia AMC2100E Electromagnetic Flow Converter

Electromagnetic AMC2100E Series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming, and troubleshooting. AMC 2100E series converter with temperature/energy.

Alia AMF601 electromagnetic flow meter
Alia AMF601 electromagnetic flow meter

AMC2100E Series

Electromagnetic AMC2100E Series Converter With temperature/energy function can be used with AMF series flowmeter in both compact or separate versions.

Features

  • Four line LCD display Flowrate/Energy/Totalizer
  • Accuracy of +/-0.4% of reading
  • Bi-directional flow measurement, current and pulse output
  • Large digital display, With temperature/energy function
  • 99 times records for power on/off
  • MODBUS/HART communication

Electromagnetic AMC2100E Series Specifications

Excitation: Keyboard:
Square wave 4 keys from external for programming
Display: and display control.
4 lines LCD with backlight Low Flow Cutoff:
Line 1 0 to 9.9 %
Date and Time Datalogger Function:
Line 2 99 times records for power on/off
6 digit flowrate Record Data:
7 digit energy value Date/Time when Power on/off
Fault code  99 years flow rate/energy/
Supply temperature Temperature / Total flow / Total energy
Line 3 One Record Data per Hour
9 digit totalizer for forwarding/ reverse flow Damping:
9 digit totalizer for heat / cold  energy 0.1 to 99.9 Second
Fault code content Self Diagnosis:
Return temperature The following error message is
Line 4 indicated during application
Differential temperature – Coil fail
Unit – Power fail
L/S, L/M, L/H, M3/S, M3/L, M3/H – Output overaged
KW, MW, KJ/H, MJ/H, GJ/H – Internal error
Measuring Range: – Overflow
Min.  0 to 0.15 m/s – Empty pipe
Max. 0 to 15 m/s Cable Entry:
Accuracy: PG11
+/-0.4% of reading (Velocity >= 0.5 m/s) Protection Class:
+/-0.002 m/s (Velocity < 0.5 m/s) IP 65
Repeatability: Ambient Temperature:
+/-0.1% of reading -25 to +65 oC
Current Output: Material:
4-20 mA (Isolated) Aluminum Alloy
Load Temperature Input:
Max. 600  PT1000, 2 wire
Pulse output: Power Supply:
Open collector 90-260 VAC, 50/60 Hz
Rating 24 VDC +/- 10% (Option)
3 to 30 VDC, 20 mA Max. Power Consumption:
Pulse Rate: 3-17 W (depending on the sensor size)
1)Scale pulse, (Pulse/M3, Pulse/L,
Other)
Weight:
2)Frequency, 0-5000 Hz 1.4 Kg
Communication: Mounting:
RS 485(MODBUS Protocol) Wall mounting
HART signal Bracket on 2″ pipe
Data Storage:
Operation parameters and totalization
figures are stored by EEPROM for more than 10 years

 

Read Another Article :

Share