Emerson Rosemount 2051HT Hygienic Pressure Transmitter

General Information

Emerson Rosemount 2051HT Hygienic Pressure Transmitter provides a reliable solution for gage and absolute measurements in the life science and food and beverage industries. This transmitter offers Emerson’s proven pressure sensor technology along with industry-standard process connections. A full suite of hygienic certifications, including 3-A® and EHEDG, as well as an optional polished stainless steel housing, ensure this device will be able to meet the requirements of your application.

Emerson Rosemount 2051HT Feature

  • Rosemount Coplanar™plat form enables the integration of primary elements, manifolds, and remote seal solutions
  • IEC 62591(WirelessHART®)Protocol enables cost-effective installations
  • Local Operator Interface (LOI) offers easy to use configuration capabilities at the transmitter
  • Protocols available include HART®4–20mA, FOUNDATION™Fieldbus, PROFIBUS®PA,HART1–5VdcLow Power
  • Selectable HART Revision prepares your plant for the latest HART capabilities while ensuring seamless integration with today’s systems
  • SIL2/3safety certification to IEC61508 is available with the full 4–20mA HART offering to simplify compliance
  • Connects to various industry-standard sanitary fittings
  • Polished stainless steel housing is free of voids and crevices to ensure easy cleaning and wipe downs
  • Offers up to 0.1% reference accuracy and 2-year stability
  • Withstands washdown conditions (up to IP69k rated) for long-term performance and durability
  • Local Operator Interface (LOI) for simple, local commissioning on-site without the use of extra tools
  • Utilizes proven Emerson sensor technology
  • Hygienic design conforms to 3-A® and EHEDG standards
  • Rated for SIP/CIP process temperatures up to 302 °F (150 °C)
  • Rangeability of 50:1
  • Proven technology from Emerson improves process reliability and robustness

Emerson Rosemount 2051HT Specification

modelsStandardHigh-performance option, P8
Rosemount 2051C
Range 1±0.10% of span
For spans less than 15:1, a
N/AN/A
Ranges 2–4±0.065% of span
For spans less than 10:1
Ranges 2–4±0.05% of span
For spans less than 10:1(1),
Range 5±0.075% of span
For spans less than 10:1
Range 5±0.065% of span
For spans less than 10:1
Rosemount 2051T, 2051G
Ranges 1–4±0.065% of span
For spans less than 10:1
Ranges 1–40.05% of span
For spans less than 10:1(1)
Range 5(2)±0.075% of span
For spans less than 10:1
N/AN/A
Rosemount 2051L
Ranges 2–4±0.075% of span
For spans less than 10:1
N/AN/A
  1. For protocol code F,  accuracy specification is for spans less than 7:1. Not available with output code W.
    2. Rosemount 2051G is not available with Range5.