Erdco 25D Turbo-Flo Flow Meter

General Information

Erdco 25D Turbo-Flo offer the precision of turbine technology with rugged construction. The practical design of the probe includes a bluff bar that protects the turbine from foreign materials in the stream as well as from over-insertion. Installation is simple and does not require special fittings. The Turbo-FloTM probe may be installed in standard pipe tees, through pipe saddles, welding spuds, and 1 1/2” full opening ball or gate valves.

Principle of Operation

The turbine is positioned in the mid-section of the pipe with its axis of rotation parallel with the flow stream. Fluid velocity causes the turbine, which has a ring magnet inside of its hub, to rotate in proportion to flow rate. As the turbine rotates, the magnetic field passes through a coil in the probe body, generating a pulse output in proportion to the turbine rotation speed. Flow volume is then determined from fluid velocity measurement and pipe diameter information

Erdco 25D Turbo-Flo Features

  • Delrin® non-metallic construction is ideal for water applications. Resists corrosion and mineral salt accumulation.
  • Steel or stainless steel connector fittings.
  • Adjustable insertion length for 11 ?2 to 10 inch pipe.
  • Lower cost than stainless steel probes.
  • Rugged construction for industrial environments.
  • No external power required.
  • Wide measuring range with 30:1 turndown.
  • Low mass Delrin® turbines offer improved sensitivity and long life.
  • Use standard pipe fittings for installation

Erdco 25D Turbo-Flo Applications

  • Water and other aqueous solutions
  • Chiller and cooling tower loops
  • Water treatment systems
  • Irrigation systems

Design Options

  • 15 feet or more of cable for connection to remotely mounted display/transmitter.
  • Probe mounted options include 4-20 mA signal output transmitters and displays
  • The LCD rate/total display does not require external power. Turbine rotation recharges the lithium power cell in the display.
  • Transmitters and displays can also be wall mounted. Shown:
    • TF-15350-2 Rate/total display
    • TF-15390 Rate/total display with 4-20 mA transmitter
    • TF-15385 4-20 mA transmitter (no display)
  • The wall mounted TF-15275 Series of Flow Controllers includes 4-20 mA signal output and two optional
    adjustable set points eachwith Form C 5A contacts. NEMA 4X enclosure. 85-265 VAC, 47-63 Hz.

Specifications

  • Accuracy : ±1.0%
  • Repeatability : ±0.5%
  • Linearity : ±0.5%
  • Turndown : 30:1
  • Insertion Length : 02 = 2 inches 06 = 6 inches 12 = 12 inches
  • Threshold : 0.5 ft/s or 1.22 x ID2 = GPM Liquid
  • Velocity : ft/s = 0.408 x GPM/pipe ID2,  Point Velocity = 2.625 pulses/ft/s
  • Pulse/gallon correction for uncharted pipe diameters = ID2 charted pipe Pulse/gallon ID2 uncharted pipe x charted pipe
  • Materials of Construction :
  • Probe : Delrin®
  • Connector : Steel, 303sst
  • Turbine : Delrin®
  • O-rings : Buna-n or Viton®
  • Temperature Limits : 225°F(107°C)
  • Pressure Limits : 145 psig(10bar)@ 75°F(24°C)

ERDCO reserves the right to alter design and/or specifications without notice. Viton® and Delrin® are registered trademarks of E.I. Dupont de Nemours and Co.