Small Vortex Flow Meter For Liquids Kofloc

Small Karman Vortex Flow Meter For Liquids

Kofloc FM0101/0102/0103/0105 SERIES

KOFLOC’s Karman Vortex Flow Meter FM Series provides an ideal tool for measuring and monitoring liquid flows, including cooling water and cleaning water. Since PPS resin is used for the body material, all models of the series offer superior reliability and durability.

Features

  • Simple design that minimizes a dead space
  • Measurements of very small flows available (up to 0.5 L/min)
  • Use of PPS resin has achieved a small, lightweight and rigid
  • The sensor can be used for pure water or deionized water or deionized water and chemicals (the sensor is acid-/alkali-resistant).
  • These models are in the process of application for CE Marking

Standard Specifications

ModelFM0101FM0102FM0103FM0105
Dimension (a)17.0817.0517.0532.05.00
Dimension (L)80.06.008080110
Connection (X)R3/8R1/2R1/225A
Flowrange0.5-4 L/min2-16 L/min4-40 L/min10-150 L/min
FluidsCooling
for measurementwater, cleaning water, etc.
Measuring accuracyWithin ±3.0% F.S
RepeatabilityWithin ±0.5% F.S
OutputsS Type:
4-20mA
P-Type:
Pulse (Open collector) (For w/o indicator only)
D Type:
With indicator
Supply voltage12-24VDC
Liquid temperature range0-70 Celcius
Proof pressure1MPa
Amb. temperature range0 – 50 Celcius
Amb. humidity range5-90%RH
Applicable cleanliness/ waterproofing standardsIP64 (Splashproof construction per JIS C 0920)
Material for wetted partPPS with 30% glass mixturePPS w/o glass mixture
Cable lengthW/o indicator: 2 meters long; terminated/pretended (pre-soldered)
With indicator: 3 meters long; terminated/pretended (pre-soldered)
WeightW/o indicator: 85 g (Sensor unit)165 g (Sensor unit)
With indicator: 100 g (Sensor unit)205 g (Sensor unit)

Principle Measurement

Kofloc FM31 Series Small Karman Vortex Flow Meter
Kofloc FM31 Series Small Karman Vortex Flow Meter

When a columnar object (an object that generates vortices) is placed in the flow path a of fluid, regulated Karman vortex channels, is generated at the back of the object.Since the frequency of a vortex generated is linearly proportional to the flow velocity within a given range, the flow amount can be measured by counting the number of vortices.

These series models make use of the principle. When the frequency of each vortex generated is detected by an incorporated vortex detector (piezoelectric device), the signal processing circuit outputs a signal which is linearly proportional to volume flow.

 Kofloc  Product Mass Flow