IH5815 Siko Incremental encoder

  • Robust optical standard rotary encoder
  • Resolution max. 5000 pulses/revolution
  • Through hollow shaft up to max. ø15 mm
  • Robust bearing construction
  • -40 °C … +85 °C operating temperature
  • High shock and vibration resistance

Specification

Starting torque<0.01 Nm at 20 °CIP65<0.05 Nm at 20 °CIP66/IP67Shaft load rating100 Nradial50 NaxialCable sheathPVC∼ø6.7 mmCable bending radius75 mmstatic110 mmdynamicWeight~0.4 kg

Feature Technical data Additional information
Shaft stainless steel
Housing die-cast
Speed ≤12000 rpm IP65
≤6000 rpm IP65 continuous operation
≤6000 rpm IP66/IP67
≤3000 rpm IP66/IP67 continuous operation
Moment of inertia ~6 x 10-6 kgm2

Electrical data

PP output circuit

Feature Technical data Additional information
Operating voltage 10 … 30 V DC reverse-polarity protected
Current consumption typical 50 mA ≤100 mA (no load)
Output signal level high ≥UB – 1.0 V short-circuit proof
Output signal level low ≤0.5 V short-circuit proof
Pulse frequency ≤300 kHz
Load ±20 mA max. adm.
Type of connection 1x M12 connector 5-pole, 1x pin

OP output circuit

Feature Technical data Additional information
Operating voltage 10 … 30 V DC reverse polarity protected
Current consumption typical 50 mA ≤100 mA (no load)
Output signal level high ≥UB – 1.0 V short-circuit proof
Output signal level low ≤0.5 V short-circuit proof
Pulse frequency ≤300 kHz
Load ±20 mA max. adm.
Type of connection open cable end
1x M23 connector 12-pole, 1x pin

LD output circuit

Feature Technical data Additional information
Operating voltage 5 … 30 V DC reverse-polarity protected
Current consumption typical 40 mA ≤90 mA (no load)
Output signal level high ≥2.5 V short-circuit proof, not against UB
Output signal level low ≤0.5 V short-circuit proof, not against UB
Pulse frequency ≤300 kHz
Load ±20 mA max. adm.
Type of connection open cable end
1x M23 connector 12-pole, 1x pin

signal pattern

IH5815 signal pattern

Ambient conditions

Feature Technical data Additional information
Ambient temperature -40 … 85 °C plug
-30 … 85 °C static laying of cables
-20 … 85 °C dynamic laying of cables
EMC EN 61326-1 immunity requirement of industry
Protection category IP65, IP66/IP67 EN 60529
Shock resistance 3000 m/s2, 6 ms EN 60068-2-27
Vibration resistance 300 m/s2, 10 … 2000 Hz EN 60068-2-6

Download Datasheet: Siko IH5815 Incremental encoder