Hengstler 773 Time Counter Tico the duty cycle of installations, machines and appliances. They provide information on the expiry times of warranty periods, hours of use and the countdown to the next scheduled maintenance work. For use in time-dependent controllers, we also have a series of preset time counters in our product range.
As a further complement, we can provide a series of time counters that offer versatile configuration options in an attractive, state-of-the-art design. Examples of typical applications: Maintenance interval counters, control of mixing quantities.
The members of this product family are really multitalented, feature up to three presets and can be connected up using plug-and-play connectors. They allow very high counting frequencies of up to 60 kilohertz and are universally suitable for use as pulse-counters, tachometers, timers, shift or batch counters.
Hengstler Time Counter Tico 773 Features
- Very simple operation
- Four different backlighting colours
- Large, easily read display
- Counting frequency up to 60 kHz
- Three presets
- Prescaler 0.0001 – 99.9999
- USB Interface
- Programming assistant (Windows XP 32 bit, Windows Vista 32 bit, Windows 7 32 bit)
Another Article: |
Specification
Product Family | tico 773 |
Function | Time counter |
Technology | Electronic |
Digits | 6-digit |
Display | 6-digit |
2-line | |
counting display/presets | |
leading zero suppression | |
decimal point (up to 4 places) | |
Preset | 3 presets |
Interface | USB interface |
Digit Height [mm] | 1. Line 9.3 mm (0.4 in) |
2. Line 7.2 mm (0.3 in) | |
Display Variant | reflective LCD |
transflective positive LCD, black digits, backlit | |
transmissive negative LCD, white digits, red or green backlit, background black | |
View Angle | 12.00 |
Relay | 1 or 2 relays |
Time Base (Tachometer) | programmable, sec |
min | |
h or hh.mm.ss | |
Measuring Principle (timer) | pulse width or period duration measurement (start-stop) |
start Inp. A + Stop Inp. B, | |
Start/Stop button | |
Function Time Counter | Single pulse measurement or cumulative measurement |
Application Input/Output (Timer) | Output: preset 0-out |
input: additional Run | |
Stop | |
Reset | |
Set | |
Keylock | |
Teach in | |
Accuracy of the Timer | Time base. ± 30 ppm |
Start / Stop time point: 16 µs / 16 ms (unattenuated / attenuated) | |
resolution: 100 µs = 100 ppm | |
Overall Tolerance (Timer) | = display resolution + tolerance time base = 130 ppm |
Resolution | 1, 0.1, 0.01, 0.001, 0.0001 |
Download Data Sheet: Time Counter Tico 773