53-SY SMC Pneumatic Solenoid Valves – 5 Port

53-SY SMC Pneumatic Solenoid Valves – 5 Port is a intrinsically safe SY valve that designed to be used in hazardous location by limiting the energy that could cause ignition when used with properly sized barriers.

Feature

  • UL Certified Intrinsically Safe Valve
  • Designed for Use in Intrinsically Safe Environment
  • UL913 & CSA157 Compliant
  • Compact type
  • Easily maintained by adapting connector for the lead wire (L- and LL-type)
  • IP65 compliant (TT-type)

Specification

  • Single Unit Body Ported
Series 53-SY5000 53-SY7000 53-SY9000
Fluid Air
Internal pilot 2-position single 20 to 100 psi (0.15 to 0.7 MPa)
operating pressure range 4-position dual 3 port valve
2-position double  15 to 100 psi (0.1 to 0.7 MPa)
3-position  30 to 100 psi (0.2 to 0.7 MPa)
Ambient and fluid temperature 15 to 120°F (–10 to 50°C) (No freezing)
Max. operating frequency (Hz) 2-position single, double 5
4-position dual 3 port valve
3-position 3
Manual override (Manual operation) Non-locking push type,
Push-turn locking slotted type,
Push-turn locking lever type
Pilot exhaust method Main/Pilot valve common exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s²) Note) 150/30
Enclosure IP30 (L-type), IP40 (LL-type), IP65 (TT-type)
  • Type 20 Body Ported Manifold Bar Stock Type
Model 53-SS5Y5-20 53-SS5Y7-20
Applicable valve 53-SY5◻20 53-SY7◻20
Manifold type Single base B mount
P (SUP)/R (EXH) Common SUP/EXH
Valve stations 2 to 20 stations Note 1)
A, B port location Valve
Port size P, EA, EB port 01-Apr
A, B port 01-Agu 01-Apr
C4 (ø4 One-touch fitting) C8 (ø8 One-touch fitting)
C6 (ø6 One-touch fitting) C10 (ø10 One-touch fitting)
C8 (ø8 One-touch fitting) N7 (ø1/4″ One-touch fitting)
N3 (ø5/32″ One-touch fitting) N11 (ø3/8″ One-touch fitting)
N7 (ø1/4″ One-touch fitting)
N9 (ø5/16″ One-touch fitting)
Manifold base weight W (g) W = 36n + 64 W = 43n + 64
n: Stations

Note 1) For 10 stations or more (5 stations or more for the 53-SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Options” on page Datasheet

  • Type 41 & 42 Base Mounted Manifold Bar Stock Type
Model 53-SS5Y5-41 53-SS5Y5-42 53-SS5Y7-42
Applicable valve 53-SY5◻40 53-SY7◻40
Manifold type Single base B mount
P (SUP)/R (EXH Common SUP/EXH
Valve stations 2 to 20 stations Note 1)
A, B port location Location Base
Direction Side
Port size P, EA, EB port 01-Apr
A, B port 01-Agu 01-Apr 01-Apr
C6 (ø6 One-touchfitting) C6 (ø6 One-touchfitting) C10 (ø10 One-touchfitting)
C8 (ø8 One-touchfitting) C8 (ø8 One-touchfitting) N11 (ø3/8″ One-touch fitting)
N7 (ø1/4″ One-touch fitting) N7 (ø1/4″ One-touch fitting)
N9 (5/16″ One-touch fitting) N9 (5/16″ One-touch fitting)
Pilot exhaust method W = 61n + 101 W = 79n + 127 W = 100n + 151

Note 1) For 10 stations or more (5 stations or more for the 53-SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Options” on page 37.