Description

Nitto Kasei PLASEAL NF-23 for Vessel and Offshore PLASEAL NF-23, used for sealing electric cable penetrations in any commercial vessels and offshore. Nitto Chemical Industry Co., Ltd., a specialized sealing compound/putty maker, produced and released “original Japan-made” fire-tight putty products. PLASEAL NF-23 takes great initiative in complying with the 2010 FTP Code and passing IMO Res. MSC. 307(88) -2010 FTP Code for A-class cable transits, which means applicable on a global scale.
Also, PLASEAL NF-23 helps save the vessel’s weight with its low specific gravity (approximately 0.8) and, most importantly, ensures super easy-to-use application under any cable transit conditions with its one-component typed material and the features of its pliable, moldable, and flexible performance. As for actual record references, PLASEAL NF- 23 has almost 100% Japanese marketing record for vessel use and gradually extends to abroad such as Asia and Southeast Asia. Besides of 2010 FTP Code, PLASEAL NF-23 is certified by a variety of ship classification societies such as ABS, BV, CCS, DNV-GL, KR, LR, NK, MED, etc.
Features
PLASEAL NF-23 helps saving vessel’s weight with its low specific gravity (approximately 0.8) and, most importantly, ensures super easy-touse application under any cable transit conditions with its one-component typed material and the features of :
- Pliable
- Moldable
- Flexible performance.
Applications
- Commercial vessel: Bulk carrier, Tanker, PCC, LNG/LPG carrier, Container ship, Passenger ship, etc.
- Offshore: Drillship, FPSO, PSV, AHTS
Specifications
Condition of construction (A-0 class)
RECTANGULAR COAMING | CIRCULAR COAMING | |||
BULKHEAD | DECK | BULKHEAD | DECK | |
Maximum size | 300?×800? | ?204.7? | ||
Minimum size | 50?×100? | ?35.7? | ||
The total cross-sectional area of the cables | 39.2? | 39.3? | ||
Minimum length of coaming | 100? | 100? | ||
Maximum measurement of the outside diameter of a cable | 73.0? | 56.4? | ||
Contact between the cables | ? | ? | ||
Contact between a cable and coaming | × | × | ||
Insulation | No need | No need |
Condition of construction (A-15/A-30/A-45 Class)
RECTANGULAR COAMING | CIRCULAR COAMING | |||
BULKHEAD | DECK | BULKHEAD | DECK | |
Maximum size | 300?×800? | ?204.7? | ||
Minimum size | 50?×100? | ?35.7? | ||
The total cross-sectional area of the cables | 39.2? | 39.3? | ||
Minimum length of coaming | 100? | 100? | ||
Maximum measurement of the outside diameter of a cable | 73.0? | 56.4? | ||
Contact between the cables | ? | ? | ||
Contact between a cable and coaming | × | × | ||
Insulation | Partially Insulation | Partially Insulation | ||
*Less than 175mm×225mm (BULKHEAD) : The total cross-sectional area of the cables is 31.2?
Fore More Information and Price: Nitto Kasei PLASEAL NF-23 for Vessel and Offshore