To measure wind velocity and direction at the fast response!

Feature
- Adopting a new sensor, improved environmental resistance performance.
- 3-D measurement of horizontal and vertical wind speed(blowing up and down) is possible.
- The measurement from 0 m/s to 60 m/s with high response and linearity.
- Without moving part, free from damage under the strong wind condition.
Another Article: |
Observation Purpose
- For environmental monitoring
- To the low layer weather and a local meteorological observation
- To the atmospheric diffusion observation
- To the operations administrator of transportation
Specification
- Measurement method:Time sharing transmission/reception switching type ultrasonic pulse emission
- Processing method :Ultrasonic propagation reciprocal difference method
- Measuring range:0 – 60 m/s (wind velocity)(Selectable from any of 1,2,5,10,15,20,30,40,50,60m/s) 0 – 540゚ (wind direction)
- Accuracy:±(3% of Reading value+0.05m/s) (wind velocity) ±3゚
(wind direction) - Output resolution :0.01m/s (wind velocity) 0.1゚(wind direction)
- Sampling rate :4 times/sec.(Option: 10 times/sec . or 20 times/sec.)
- Digital output:RS-422(can output any element signal)
- Analog output :0 – 20mA or 4 – 20mA(4CH) (Select any output signal by 4 elements)
- Output signal :
-
- Momentary wind velocity(Ui)
- Momentary wind direction(θi)
- Momentary vertical wind velocity(Wi)
- Momentary wind velocity(Xi, Yi)
- Vector averaged wind velocity(Um)
- Vector averaged wind direction(θm)
- Averaged vertical wind velocity(Wm)
- Scalar average wind velocity(Us) A
- average wind velocity(Xm, Ym)
- Average wind velocity of 3sec movement(U3)
- Option (Sonic virtual temperature (T) *1)
- *1: Available only for 10times/sec. or 20 times/sec. selected
- Averaging time:1 – 15 min.(can be set at every minute)
- Protection circuit:Overcurrent protection, Surge protection
- Main material :Stainless
- Painted color:Silver (equivalent to Munsell N8)
- Temperature :- 20 ~+50°C
- Humidity:10 ~ 95%RH
- Power supply:DC24V 4W
- Weight:Approx. 4.5kg
- Digital output details :
- Communication speed: 1200,2400,4800,9600,19200bps
- Data length/8bit,
- Parity/None,
- Stop bit/1bit
- >Output format/ASCII
- Elements/Element of wind speed is output in CSV format
- Option: Heater (Specifications: DC24V 60W with 50m cable)
Configuration Item
- SAT anemometer/SAT-600 : 1unit
- Accessory/Display & setting software :1set
- Connection cable/JCS-20S(20m): 1pc.
- Option unit
- Power supply signal converter /SAT-PJBA
- Surge protection device(Outdoor)/SAT- SPS
- Surge protection device(Indoor)/SAT- S
Reference: Sonic SAT-600 Ultrasonic Anemometer 3-D