Bamo HygroWiz Relative Humidity and Temperature

Description

Bamo HygroWiz Relative Humidity and Temperature measures the temperature and relative humidity of the air. The temperature and humidity probe is integrated or cable connected to the housing. Standard version: the probe has a PTFE tap filter to limit the impact of water splashes (non-absorbent and anti-corrosion surface).

Choose the right version for your application, with remote signals, relay outputs, 4-20 mA signals, interface RS485 MODBUS protocol. Please, request more information when necessary. HygroWiz is available as a blind version, without display. For an easy start-up, HydroWiz is set up by ourselves before shipment, according to your needs (to list them on P.O.).

Bamo HygroWiz Relative Humidity and Temperature Features

  • Local or remote display
  • Analogue output(s) 4-20 mA
  • Relay output(s)
  • Interface RS485 with MODBUS RTU

Application

  • For automation of HVAC network
  • Storage areas, cool stores, greenhouses, animal husbandry
  • Museums, Data centers, weather stations

Bamo HygroWiz Relative Humidity and Temperature Specification

Power supply 24 V DC (11 … 36 V DC) – Consumption maxi 2.5 W
Display Backlit, graphic LCD – 128 x 64 pixels
Ambient temperature -20 … +70 °C (Version without display: -30 … +80 °C)
Protection IP 65 (Version without display: IP 67)
Housing Wall mounting
Dimensions: 120 x 90 x 50 mm
Materials: ASA ( Luran® ) and polycarbonate
Probe for QM-212 model:
Type Integrated to the display unit
Dimensions Height: 90 mm; O.D.: 18 mm
Materials: AISI 316 L; PTFE tap filter
Temperature -30 … +105 °C (±0,2 °C from 10 to 60 °C)
±0.4 °C at 30 °C ; ±0.7 °C at 105 °C
Humidity 0to 100 % RH (±1.8 % RH from 20 to 80 % RH at 25 °C)
Probes for QM-612 model:
Type Output cable, to connect to the housing
Dimensions Length: 90 mm; O.D. 18 mm
Materials AISI 316 L; PTFE tap filter
Cable with PUR coating: Max. 80 °C; Or TPE: Max. 120 °C
Temperature -40 … +120 °C (± 0.2 °C from 10 to 60 °C)
( ±0.4 °C at -30 °C ; ±0.7 °C at 120 °C )
Humidity 0… 100 % RH ( ±1.8 % RH from 20 to 80 % RH at 25 °C )
Connections Cable gland or connector type M12 – 4 pins
Outputs (options): 0, 1 or 2 relay outputs, N.O.
Relay outputs Rated: 24 V AC / 35 V DC, 200 mA
Analogue outputs 0, 1 or 2 outputs: 0/4-20 mA (0/24 mA max.)
Active signal, no galvanic insulation
Interface RS485; 8N1 & 8N2; 1,200 … 115,200 bit/s; MODBUS RTU; no galvanic insulation

Download Data Sheet: Relative Humidity and Temperature HygroWiz

Reference: bamo.eu

Another Article:

Similar Posts