Description of Gastec GHS-8AT-EX Hydrogen Sulphide Data Logger

H2S continuous monitoring is simple, convenient, and reliable.
When corrosive hydrogen sulfide is produced in the sewer system, it causes rust and releases subsurface odors.
In the worst situation, buildings and facilities are severely damaged by H2S gas.
Continuous sewer system monitoring is made feasible with the GHS-8AT-EX data logger.
The sewer system, sewage pipeline corrosion, and the source of foul odors are all continuously monitored.
- The large display screen enables you to check concentration, temperature, and remaining battery capacity. The product also comes with a function that notifies you of when the sensor must be calibrated.
- The use of a power supply and a recording switch enables energy to be conserved and also enables you to freely select the start and end points of recording.
- Small and light weight
- You can easily remove the outer case to replace it.
- The water resistance and corrosion resistance of the structure have been enhanced (IP66/67), and the product is designed to float on water.
- Even when logging is performed for one minute, up to one month’s worth of concentration and temperature data can be recorded.
- We manufacture sensors for a wide range of measurement applications to match a variety of measurement locations.
Specification of Gastec GHS-8AT-EX Hydrogen Sulphide Data Logger
Model No. | GHS-8AT-EX | |||||
Application | Hydrogen Sulphide | |||||
H2S Sensor | Controlled potential electrolysis sensor | |||||
Sampling method | Diffusion | |||||
Sensor range | 0 – 10.0ppm | 0 – 100ppm | 0 – 500ppm | 0 – 1000ppm | 0 – 3000ppm | |
Sensor code | H2S-520E | H2S-521E | H2S-522E | H2S-523E | H2S-524E | |
Accuracy *1 | ±5?of F.S. | ±5?of F.S. | ±5?of F.S. | ±5?of F.S. | ±5?of F.S. | |
Increments | 0.1ppm | 1ppm | 1ppm | 10ppm | 25ppm | |
Temperature measuring range | 0? – 40? | |||||
Temperature sensor | CMOS Temperature sensor | |||||
Temperature accuracy | ±3? | |||||
Display | LCD Display (concentration, temperature, time, battery life, remaining data capacity in days) | |||||
Log type | Selectable from instant, average, peak, minimum | |||||
Operating temperature and humidity ranges | Temperature: 0 – 40? Humidity: 30 – 95%RH (Non-condensing) | |||||
Power supply | 2 x AA Alkaline batteries. Only the following types may be used: LR6(Panasonic) MN1500(DURACELL) | |||||
Battery life | 3 months *2 | |||||
Battery for memory backup and clock | 1 x Lithium battery Typical battery life: 5 years *3 | |||||
Clock error | ±10 seconds/day (25?) | |||||
Data logging capacity | 45960 points *4 | |||||
Logging interval | 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes | |||||
Communication interface | USB2.0 | |||||
Dimensions | 89 x 148mm (approx.) | |||||
Weight | 390g (approx.) | |||||
Standard accessories | H2S sensor, String (5m), Screw lock stainless ring catch (oval, triangle), Ball Allen driver, Screwdriver, AA battery (2), sensor filter (6), Dedicated software ANASYS, USB cable (1m), Instruction manual. | |||||
EU Directive | 2014/34/EU(ATEX), 2014/30/EU(EMC), 2011/65/EU, (EU)2015/863(RoHS), (EU)2023/1542(BATTERY) | |||||
Marking | ATEX | II2G Ex ia IIB T3 Gb | ||||
IEC Ex | Ex ia IIB T3 Gb | |||||
Certificate Number | ATEX | DEKRA 14ATEX0135 | ||||
IEC Ex | IECEx DEK 14.0085 | |||||
Standards | ATEX | EN IEC60079-0:2018 , EN60079-11:2012 | ||||
IEC Ex | IEC60079-0:2017 , IEC60079-11:2011 | |||||
EMC | EN50270:2015, EN55032:2015+A11:2020+A1:2020, EN55035:2017+A11:2020 | |||||
RoHS | EN IEC63000:2018 |
For More Information and Price: Gastec GHS-8AT-EX Hydrogen Sulphide Data Logger
Read More Articles:
- Shand & Jurs 94040 Spring Loaded Conservation Vent
- Dwyer Series 1950G Explosion-proof Differential Pressure Switch
- Dwyer H3 Explosion-Proof Differential Pressure Switches
- Dwyer 1950 Explosion-proof Differential Pressure Switch Low
- GPE 31611 Capacitance Center Sensor
You must be logged in to post a comment.