Leuze Sensor DDLS 200 optical data transceiver from Leuze electronic transmits data from industrial networks via infrared light without contact or wear. Transmission is fast, deterministic and immune to interference. The method of function is absolutely transparent: This means that the optical data transceiver does not represent a participant on a given network, but rather handles data communication without intervening in the communication process. Thus, it functions as reliably and as simply as a copper cable.

- The optical data transceivers are used primarily in plant engineering, especially in applications where industrial networks such as PROFIBUS, DeviceNet or Ethernet etc. are transmitted to system components which are moved. Examples include high-bay storage devices, gantry crane bridges or side-tracking skates.
- The DDLS 200 supports all of the major international interfaces
- Infrared data transmission protects the DDLS 200 from interference.
- The fast transmission rates and enormous operating ranges of up to 500 m make the DDLS 200 an essential centrepiece in modern plant engineering.
Features
- Integrated mechanics for fastening and aligning the data path. The result: very simple mounting.
- Robust metal housing with protection class IP 65 offers optimum protection against electromagnetic interference injection.
- M12 connections with ready-made cables make the connection of additional M12 participants incredibly simple and error free.
- The integrated and patented alignment method facilitates the alignment of both devices by one person and can be activated with a simple push of a button.
- One for all. The DDLS 200 series supports all major international interfaces such as PROFIBUS, Ethernet, DeviceNet, CANopen etc. Individual approvals, such as UL for the American market, have been obtained.
- The integrated control panel with diagnostic functions provides extensive information on the status of the data communication. Signal strengths, transmitted and received data, the alignment or light beam interruptions are reliably displayed.
Application
During use in extreme environmental conditions, e.g. outdoors or in deep-freeze warehouses, integrated heating ensures reliable and fault-free operation at temperatures as low as -30 °C.
Specification
Electrical data | |
Supply voltage | 18 … 30 V DC |
Current consumption without optics heating | approx. 200 mA with 24 V DC |
Current consumption with optics heating | approx. 800 mA with 24 V DC |
Optical data | |
Opening angle | ± 0.5° with respect to the optical axis for 120 m … 500 m models |
± 1.0° with respect to the optical axis for 80 m models | |
± 1.5° with respect to the optical axis for 30 m models | |
Input/output | |
Input | 0 … 2 V DC: transmitter/receiver deactivated 18 … 30 V DC: transmitter/receiver activated |
Output | 0 … 2 V DC: normal operation Vin – 2 V DC: limited performance reserve Output current max. 100 mA, short-circuit proof |
Operating and display elements | |
Membrane buttons | change of operating mode |
Individual LEDs | indicate voltage supply, operating mode, data traffic (depends on the model) |
LED strip | bar graph display of the receiving level |
Mechanical data | |
Protection class | IP 65 acc. to EN 60529 |
Weight | approx. 1200 g |
Housing | aluminium diecast; light inlet/outlet, glass |
Environmental data | |
Operating temperature | -5 °C … +50 °C without integrated heating -30 °C … +50 °C with integrated heating (non-condensing) |
Air humidity | max. 90 % rel. humidity, non-condensing |
EMC | EN 61000-6-2:2005 and EN 61000-6-4:2001 |
UL listed | acc. to UL 60950 and CSA C22.2 No. 60950 |
For More Information and Price: Leuze Sensor DDLS 200 with 2?Mbit/s transmission rate
Read More Articles:
- Neodyn 100P NEMA 4X, 7, 9 and 13 Internal Adjustment
- Neodyn 101P NEMA 4 and 13 External Adjustment
- Neodyn 105P NEMA 1 and 2 Miniature Tamper Proof
- Neodyn 110P NEMA 4 and 13 Pressure Switch
- Neodyn 112P NEMA 4X, 7, 9 and 13 Flanged Diaphragm Sensor
You must be logged in to post a comment.