Omron E2EY Aluminum Detecting Proximity Sensor

Omron E2EY Aluminum Detecting Proximity Sensor use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models.

OMRON Sensing Components detect, measure, analyze, and process various changes that occur on productions sites, such as changes in position, length, height, displacement, and appearance. They also contribute to predicting and preventing future events.

Omron E2EY Aluminum Detecting Features

  • Non-ferrous metals, such as aluminum and brass, are detected. *
  • Ferrous metals, such as iron and nickel, are not
  • Aluminum foil, however, cannot be detected.

Another Article:

Rating and Specifications

Item                                Model E2EY-X4C1 E2EY-X8C1
Sensing distance 4 mm ±10% 8 mm ±10%
Set distance 0 to 2.8 mm 0 to 5.6 mm
Differential travel 20% max. of sensing distance
Detectable object Non-ferrous metal (Does not detect ferrous metal.)
Standard sensing object Aluminum: 18 ´ 18 ´ 1 mm Aluminum: 30 ´ 30 ´ 1 mm
Response frequency * 70 Hz
Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 20 mA max.
Control output Load current NPN open-collector output, 100 mA max. (at 30 VDC)
Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators Detection indicator (red)
Operation mode (with sensing object approaching) Load ON: NO (Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.)
Protection circuits Reverse polarity protection, Load short-circuit protection, Surge suppressor
Ambient temperature range Operating/Storage: -10 to 55°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±20% max. of sensing distance at 23°C in the temperature range of -10 to 55°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in rated voltage ±15% range
Insulation resistance 50 MÙ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 140 g Approx. 190 g
 

 

Materials

Case Nickel-plated brass
Sensing surface Heat-resistant ABS
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories
  • The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.