Wenglor OCP352H0180 Photoelectronic Sensor

Wenglor OCP352H0180 sensors work with a high-resolution CMOS line and DSP technology and determine distance using angular measurement. As a result, material, color, and brightness-related measurement differences are virtually eliminated. The integrated analog output can be configured for voltage 0…10 V (10…0 V) or current 4…20 mA (20…4 mA).

  • Linearity: 0,15 % (resolution-mode)
  • High resolution: 50 µm (resolution-mode)
  • Zoom function
  • Measured value independent of material, color, and brightness

Wenglor OCP352H0180 Specification

Optical Data

Working Range 50…350 mm
Measuring Range 300 mm
Resolution 50 µm
Resolution (Speed-Mode) 80 µm
Linearity 0,15 %
Linearity (Speed-Mode) 0,2 %
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 18…30 V DC
Current Consumption (Ub = 24 V) < 80 mA
Measuring Rate 500 /s
Measuring Rate (Resolution-Mode) 250 /s
Response Time < 2000 µs
Response Time (Resolution Mode) < 4000 µs
Temperature Drift < 25 µm/K
Temperature Range -25…50 °C
Analog Output 0…10 V/4…20 mA
Load Current Voltage Output < 1 mA
Current Output Load Resistance < 500 Ohm
Interface RS-232
Baud Rate 38400 Bd
Protection Class III
FDA Accession Number 1120723-000

Wenglor OCP352H0180 Mechanical Data

Setting Method Teach-In
Housing Material Plastic
Degree of Protection IP67
Connection M12 × 1; 8-pin

Output

Error Output yes
Analog Output yes
RS-232 Interface yes

Datasheet: Wenglor OCP352H0180 Photoelectronic sensor

Reference: wenglor.com