Schneider RM35TF30 Relay Fase Multifungsi
Schneider RM35TF30 Relay Fase Multifungsi termasuk dalam kategori zelio control relay dengan multifungsi yang digunakan untuk mendeteksi kegagalan fase, melihat overvoltage & undervoltage, Asimetris, dan urutan fase.

Spesifikasi
| Main | |
|---|---|
| tipe produk/component | Pengukuran modular dan kontrol relay |
| tipe relay | relay fase multifungsi |
| Detail aplikasi produk | Untuk pasokan 3 fase |
| time delay | Disesuaikan 0.1…10 s, +/- 10 % dari nilai skala penuh |
| kapasitas swicthing dalam VA | 1250 VA |
| rentang pengukuran | 208…480 V voltage AC |
| Complementary | |
| reset time | <= 1500 ms for at 480 V |
| maximum switching voltage | 250 V AC |
| 250 V DC | |
| minimum switching current | 10 mA at 5 V DC |
| maximum switching current | 5 A AC |
| 5 A DC | |
| supply voltage limits | 194…528 V AC, 3 phases |
| batas control circuit voltage | – 12 % + 10 % Un |
| komsumdi daya VA | 0…22 VA at 400 V AC 50 Hz |
| voltage detection threshold | < 194 V |
| control circuit frequency | 50…60 Hz +/- 10 % |
| output contacts | 2 C/O |
| nominal output current | 5.00 AM |
| measurement voltage limits | 176…528 V AC |
| hysteresis | 2% |
| delay at power-up | <= 650 ms |
| measuring cycle | <= 140 ms measurement cycle as true rms value |
| threshold adjustment voltage | +2…+10 % in the range 480 V AC |
| -12…-2 % in the range 220 V AC | |
| 2…20 % of Unselected | |
| -20…-2 % in the range 380…480 V AC | |
| +2…+20 % in the range 220…440 V AC | |
| voltage range | 220…480 V phase to phase |
| adjustment of asymmetry threshold | 5…15 % of Unselected |
| repeat accuracy | 0.3 % for time delay |
| 0.5 % for input and measurement circuit | |
| measurement error | < 1 % over the whole range with a voltage variation |
| 0.05 %/°C with temperature variation | |
| response time | < 200 ms in the event of a fault |
| marking | CE |
| overvoltage category | III conforming to IEC 60664-1 |
| insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 |
| > 500 MOhm at 500 V DC conforming to IEC 60664-1 | |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| supply frequency | 50/60 Hz +/- 10 % |
| operating position | Any position without |
| connections – terminals | Screw terminals 1 x 0.5…1 x 4 mm² – AWG 20…AWG 11, solid cable without cable end |
| Screw terminals 2 x 0.5…2 x 2.5 mm² – AWG 20…AWG 14, solid cable without cable end | |
| Screw terminals 1 x 0.2…1 x 2.5 mm² – AWG 24…AWG 12, flexible cable with the cable end | |
| Screw terminals 2 x 0.2…2 x 1.5 mm² – AWG 24…AWG 16, flexible cable with the cable end | |
| tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| housing material | Self-extinguishing plastic |
| local signaling | LED green for power ON |
| LED yellow for relay ON | |
| LED yellow for fault | |
| mounting support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
| electrical durability | 100000 cycles |
| mechanical durability | <= 30000000 cycles |
| operating rate | <= 360 operations/hour under full load |
| utilization category | AC-12 conforming to IEC 60947-5-1 |
| AC-13 conforming to IEC 60947-5-1 | |
| AC-14 conforming to IEC 60947-5-1 | |
| AC-15 conforming to IEC 60947-5-1 | |
| DC-12 conforming to IEC 60947-5-1 | |
| DC-13 conforming to IEC 60947-5-1 | |
| safety reliability data | MTTFd = 399.5 years |
| B10d = 360000 | |
| width | 35 mm |
| product weight | 0.13 kg |