Kofloc DF-300C Series Digital Mass Flow Controller with Indicator is a mass flow controller with an integral indicator that operates on a 24-V power supply, as developed in response to the requests from users of the DF Series.
It inherits the features of the DF-200C Series with enhanced convenience, including accuracy of ±1% S.P., response 1 sec (in all ranges), and the multiple-gas, multiple-range versatility, i.e., support of seven gases (including reference gas) and the ease of changing the flow rate range of each gas.
Kofloc DF-300C Series Features
- High accuracy (±1% S.P.), fast response (? 1 sec in all ranges)
- Support of multiple ranges and multiple gases
- Communication functions installed as a standard feature (RS485)
- RoHS CE standard compliant
- Driven by a single 24 V DC supply voltage
- With or without indicator (selectable)
- Selectable Input/output signal
Specification
| Sensor type | Thermal sensor | |
| Valve type | Normally closed proportional solenoid valve | |
| Applicable gases1 | N2 (Air, H2, He, Ar, O2, CO2) 2 | |
| Flow range 3 | 10/30/50/100/300/500 SCCM, 1/3/5/10 SLM2 | |
| Control range | 2 to 100% (F.S.) | |
| Response 4 | Total flow rate control range ±1 sec (within ±2% F.S.) | |
| Accuracy 5 | ±1.0% S.P. (> 35% F.S.) ±0.35% F.S. (? 35% F.S.) | |
| Repeatability | ±0.25% F.S. | |
| Operating differential pressure 6 | 50 to 300 kPa (100 to 300 kPa for Ar and CO2) | |
| Inlet maximum pressure | 500kPa G | |
| Proof pressure | 980kPa G | |
| External leak rate | 1.0 x 10-8 Pa·m3/sec (He) | |
| Temperature | Working temp. | 5 to 50 |
| Accuracy guaranteed temp. | 15 to 35 | |
| Allowable storage temp. | -10 to 6 | |
| Permissible ambient humidity Allowable operating humidity | 10 to 90% RH (without dew condensation) | |
| Materials of a gas contact part | SUS316, SUS316L, magnetic stainless steel, Ni, PTFE, PCTFE, and FKM | |
| Electrical connection | D-sub15-pin male, high density, HR-10A (two) | |
| Flow rate setting signal | 0 to 5 V DC (input impedance: approx. 1 M?), or 4 to 20 mA (input impedance: approx. 250) | |
| Flow rate output signal | 0 to 5 V DC (load resistance 10 k?), or 4 to 20 mA (load resistance 500) | |
| Digital communication | Address setting with RS485 rotary switch or indicator: up to 99 devices (9600 bps) | |
| Event input | Three contact inputs (non-insulated) | |
| Event output | Three NPN open collectors (non-insulated, max. rating 35 V, 50 mA) | |
| Required power supply (DC) | +24 V DC (±10%), 300 mA max. (DC jack, D-sub) | |
| Joint 7 | 1/4 F900 (standard), 1/4 UJR, Rc 1/4 | |
| Mounting posture | Horizontal installation recommended. | |
| Weight 8 | Approx. 950 g | |
Other Articles:
- Kofloc DF-250C Series Digital Mass Flow Meter
- Kytola Seal Water Flow Meter Model SLM
- Kofloc DF-350C Digital Mass Flow Meter
- Kofloc Model 3760 Series
- Kofloc Back Pressure Valve Model 6801 Series
- Kofloc Mass Flow Controller D8500 Series
- Adapter Connector NCS-163-ADF-CH Nanaboshi
- Kofloc Model 3760 Series
- Kofloc Back Pressure Valve Model 6801 Series
- Differential Pressure Flow Meter
- Kofloc Mass Flow Meter and Controllers
- Rotameter Kofloc RK1930/RK1935
- Kofloc CK Series Flow Setting Device Model
- Kofloc 2600 All-Teflon Constant Flow Control Valve