Features & Applications
The iMAG-Series is the most economical flanged electromagnetic flowmeter on the market. With electrodes designed to discourage fouling, it is available in 3 to 12 pipe in municipal or industrial water, waste and reclaimed water, pump stations, and packaged plant applications. Minimal straight pipe requirements allow iMAG-Series meters to be used in piping configurations where there is little space between the meter and an elbow.
Features
- Easy setup
- Minimal straight pipe
- Mounted or remote rate & total
- Tamper-evident seal
- Certified to NSF/ANSI standard 61
- IP68 rated
- No moving parts

Application
- Water & Wastewater Treatment
- Municipal
- Pump skids
- Pump stations
- Packaged plants
- Filtration systems
- Reclaimed water
- Hydraulic fracturing
Specification iMAG Water Flow Meter
| Pipe Sizes | 3”, 4”, 6”, 8”, 10”, 12” | ||||
| Flanges | 150 lb. ANSI Pattern | ||||
| Pressure | Pressure 150 psi (10.3 bar) line pressure | ||||
| Temperature | Operating | 10? to 140? F (-12? to 60? C) | |||
| Storage | -40? to 158? F (-40? to 70? C) | ||||
| Accuracy | ±0.75% of reading on iMAG 4700p and 4700r (±1.0% iMAG 4700), ±0.025% of full-scale flow from low flow | ||||
| cutoff to maxi. flow rate of 10 m/sec | |||||
| Low Flow Cutoff | 0.5% of maximum flow rate | ||||
| Material | Body (3” only) | Ductile cast iron, powder-coated | |||
| Body (4”-12”) | Welded steel, epoxy-coated | ||||
| Liner (3” only) | Noryl® | ||||
| Liner (4”-12”) | Santoprene flange/Polypropylene liner body | ||||
| Electronics Housing | Powder-coated diecast aluminum | ||||
| Electrodes | 316 stainless steel | ||||
| O-ring (3” only) | EPDM | ||||
| Display | Type | 128×64 dot-matrix LCD | |||
| Digits | 5 Digit Rate | 8 Digit Total | |||
| Units Please Note: All iMAG meters are factory set for gallons per minute (GPM) rate and gallons total. If other units are required, they can be set in the field | Rate Volume Units | Rate Time Units | Total Volume Units | ||
| Gallons, Liters, Barrels(42 gal), Cubic Feet, Cubic Meters | Million Gallons², Mega Liters² Imperial Gallons, Million Imperial, Gallons² | Second, Minute, Hour, Day | Gallons, Liters, Barrels(42 gal), Cubic Feet, Cubic Meters, Second Foot Day, Million Cubic Feet. Acre Feet, Acre Inches, Imperial Gallons, Fluid Ounces | ||
| Bidirectional¹ | Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total (Batch totals can be reset) | ||||
| Power | DC Power | 9-36 Vdc @ 250 mA max, 30 mA average | |||
| Battery Backup (Not for use as primary power) | DC powered units: Two lithium 3.6V ‘D’ batteries, replaceable. | ||||
| AC powered units: One 9V alkaline battery, replaceable. | |||||
| AC Power (iMAG 4700r and 4700p only) | 85-264Vac, 50/60Hz, 0.12A | ||||
| Battery (iMAG 4700 only | One lithium 7.2V ‘D’ size battery pack, replaceable. | ||||
| Scaled Pulse | Signal | Current sinking pulse, isolated, 36 Vdc at 10 mA max | |||
| Output | Pulse Rates | User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150 pulses/sec max. | |||
| Options | 4-20mA Current Loop | Isolated, passive, 24Vdc, 650 ? maximum current loop | |||
| HART/4-20mA | HART protocol over 4-20mA line | ||||
| High Speed Digital Output (iMAG 4700 & 4700p only) | Isolated, open collector, 24 Vdc | ||||
| Serial Communications | Isolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus® RTU protocol (factory selectable) | ||||
| Cable | Power/Output Cable | 20ft (6m) standard length polyurethane jacketed cable—for power and outputs (lengths up to 200’ available). | |||
| Remote Display Cable (iMAG 4700r) | 20ft (6m) standard length polyurethane jacketed cable—for connection between meter and remote display (lengths up to 200’ available). | ||||
| Conductivity | >20 microSiemens/cm | ||||
| Empty Pipe Detection | Hardware/software, conductivity-based | ||||
| Regulatory | (EN 61326), 4”-12” certified to NSF/ANSI standard 61 60°C (140°F); 3” certified to NSF/ANSI standard 61 Cold Water 23°C (73.4°F) | ||||
| Environmental | NEMA 6P, IP68 (10ft (3m) depth, continuously) | ||||
Modbus is a registered trademark of Schneider Electric.
- Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).
- If forward and reverse flow data needs to be sent to another device, either the Digital or Modbus output is required.
- Rate Time Unit is available in Day only.
Download Datasheet: Seametrics iMAG 4700
Contact us : sales@wmablog.com or visit to our E-Commerce
Baca Juga
- Mengukur Debit Pada Bendungan Open Channel
- Water meter jenis ultrasonic flow meter tanpa memotong pipa
- Water flow sensor jenis clamp on ultrasonic flow meter
- Cara Memperlambat Putaran Meteran Air PDAM
- Flowma Flowmasonic WUF 620 J Portable Ultrasonic Flow Meter
- Flow Meter untuk Air Lumpur Limbah Pertambangan
- Flow meter Ultrasonic yang Digunakan di PLTU
- Kapasitas Flow Meter dan Flow velocity
- Open Channel Flowmeter untuk Parit, Gorong-gorong
- Flow Meter Air Kotor 14 Inch Flowma WMAG21
- Hal yang Perlu Diperhatikan dalam Proses Installasi Panel Surya
- Portable Flow Meter : Definisi, Jenis, dan Fungsi