Dynalco Monitoring Catalyst Monitor Engine Monitoring & Controls, 6 Channel Monitor / Data Logger. Designed for catalyst monitoring and data logging on Spark Ignited and Diesel engines.
- NSCR (3-way) & Oxidation (2-way) type catalysts
Dynalco was started in 1968 with three products and a goal of producing engineered solutions for the oil and gas industries. Today, Dynalco has become a worldwide industry leader, recognized for its high-quality instruments and controls used in the oil & gas, chemical, power, marine and construction industries. In October 2011 Dynalco was acquired by its sister company Barksdale, Inc. and is now part of Barksdale’s family of brands
Another Article: |
The following parameters are monitored:
- Catalyst Inlet / Outlet Temperatures plus Differential
- Catalyst Inlet / Outlet Pressures plus Differential
- Left Bank / Right Bank O2 Sensor Outputs for ensuring proper AFRC operation
- Engine Hours (5-digit non-resettable)
- Engine Speed
- Can be configured to alarm if inlet temperature out of compliance
- On-Board Data Logging of thousands of values with time / date stamp. Monitors catalyst inlet temperature based on 4 hour rolling average per RICE NESHAP requirements – data is saved to non-volatile flash memory
- Modbus RS-485 Communications Protocol for communications w/ SCADA or DCS
- CSA Class I, Division 2 Groups A, B, C & D approved
- Fully programmable from front keypad
- High capacity on board flash memory
- Power loss will not erase memory
- Log Reader software allows data download to PC with USB cable p/n 270A-13020
Dynalco Monitoring Catalyst Monitor Specification :
Electrical:
- Supply Voltage: 10 – 36 VDC
- Input Types: J, K type thermocouple
- 4 – 20 mA
- 0 – 1 VDC
- 0 – 5 VDC
- 0 – 10 VDC
- Plus (1) pulsed input for RPM display
- Output Type: (2) digital outputs rated 0.15 A @ 48 VDC
- Scan Rate: All channels scanned in 100 milli-seconds
- Accuracy: 0.2%
- Mechanical:
- ¼ DIN package (3 ½” width X 3 ½” height) for panel mount
- Splash-proof front panel
- Removable connectors on back of enclosure
Reference : dynalco.com
Download : Datasheet