Description
Tival Sensors TST 10 / 20 Pressure transmitter, The pressure transmitters of the TST 10 … / 20 … series are designed for the numerous measuring tasks and requirements in mechanical engineering, in hydraulics and pneumatics, in plant construction and in automation technology. Long-term reliability, high measurement accuracy and a robust and compact stainless steel housing are the basic features of TIVAL Sensors TST 10 … / 20 … pressure transmitters.
The measuring range of the TIVAL TST 10 … / 20 … pressure transmitter can be set individually and continuously in ranges from -1 … 0 bar to 0 … +1000 bar. As an output signal, all currently used 2- or 3-wire analog output signals are available for selection. Process port and electrical connection can be combined customer-specifically from the current versions of the present MCR technology. Further additional options such as increased measurement accuracy of 0.25% FS, connection assignments according to customer specifications or an increased IP protection class allow the TIVAL TST 10 … / 20 … to be adapted to all industrial measurement requirements.
The use of a “dry”, fully welded stainless steel measuring cell leads to high media compatibility and suitability. In addition, since no internal transmission medium is necessary, the TIVAL Sensors TST 10 … / 20 … pressure transmitter can be used in many different ways in water technology.
Product description Pressure transmitter TST 10… / 20…
- Measuring ranges from -1 … 0 bar to 0 … +1000 bar
- Output signal 4 … 20 mA (2- or 3-wire) or 0 … 10 V (3-wire)
- Dry stainless steel measuring cell and compact stainless steel housing
- Media temperature -40 … +125 °C
- Available as relative pressure or absolute pressure transmitter
Standard pressure ranges TST 10… / 20…Individual pressure ranges on request | |||||||||||
Measuring range | P(bar) | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | 16,0 | 20 | 25 |
Overpressure | P(bar) | 6 | 6 | 6 | 10 | 10 | 20 | 20 | 40 | 40 | 100 |
Bursting pressure | P(bar) | 9 | 9 | 9 | 15 | 15 | 30 | 30 | 60 | 60 | 100 |
Measuring range | P(bar) | 40 | 60 | 100 | 160 | 200 | 250 | 400 | 600 | 1000 | |
Overpressure | P(bar) | 100 | 200 | 200 | 400 | 400 | 750 | 750 | 840 | 1200 | |
Bursting pressure | P(bar) | 150 | 300 | 300 | 600 | 600 | 1000 | 1000 | 1050 | 1500 |
Technical data | Pressure transmitter TST 10… / 20… | |
Electrical parameters | TST 10… | TST 20… |
Output signal Operating voltage UB Permitted max. load RA Recommended max. load resistor RL | 4 … 20 mA (2- or 3-wire) 9 … 32 V DC RA ? (UB – 9 V) / 20 mA | 0 … 10 V DC (3-wire) 12 … 32 V DCRL > 5 k? |
Response time (10 … 90 %) | < 1 ms | < 1 ms |
Accuracy specifications | ||
BFSL | ?± 0,15 % FS | ?± 0,15 % FS |
Total error at RT
| ?± 0,50 % FS – including nonlinearity, hysteresis, zero point and full scale error (according to IEC 61298-2). Optionally available with increased measuring accuracy of ?± 0.25 % FS | |
Stability per year | ?± 0,10 % FS |
Reference : tival-sensors.com
Download : Datasheet
Other Article:
- TIVAL Sensors
- Tival Sensors TST-DD 10.0 / 20.0
- Tival Sensors TS-LSD 30
- Hengesbach TP 30 Contact Resistance Thermometer
- Prosedur Pengoprasian flowmeter portable Ultrasonic
- Tival Sensors TS-RFS Level Limit Float Switch
- Tival Sensors TS-NW3 Level Controller
- Tival Sensors Float Switch OPT for Liquid Level Control
- Tival Sensors TS-TT Temperature Transmitter
- Flux Centrifugal Immersion Pumps Type F 620
- Tival Sensors TST-PM 63
- Tival Sensors TST 10 / 20 Pressure transmitter