Tival Sensors TST 10 / 20 Pressure transmitter

Description

Tival Sensors TST 10 / 20 Pressure transmitter, The pressure transmitters of the TST 10 … / 20 … series are designed for the numerous measuring tasks and requirements in mechanical engineering, in hydraulics and pneumatics, in plant construction and in automation technology. Long-term reliability, high measurement accuracy and a robust and compact stainless steel housing are the basic features of TIVAL Sensors TST 10 … / 20 … pressure transmitters.

The measuring range of the TIVAL TST 10 … / 20 … pressure transmitter can be set individually and continuously in ranges from -1 … 0 bar to 0 … +1000 bar. As an output signal, all currently used 2- or 3-wire analog output signals are available for selection. Process port and electrical connection can be combined customer-specifically from the current versions of the present MCR technology. Further additional options such as increased measurement accuracy of 0.25% FS, connection assignments according to customer specifications or an increased IP protection class allow the TIVAL TST 10 … / 20 … to be adapted to all industrial measurement requirements.

The use of a “dry”, fully welded stainless steel measuring cell leads to high media compatibility and suitability. In addition, since no internal transmission medium is necessary, the TIVAL Sensors TST 10 … / 20 … pressure transmitter can be used in many different ways in water technology.

Product description Pressure transmitter TST 10… / 20…

  • Measuring ranges from -1 … 0 bar to 0 … +1000 bar
  • Output signal 4 … 20 mA (2- or 3-wire) or 0 … 10 V (3-wire)
  • Dry stainless steel measuring cell and compact stainless steel housing
  • Media temperature -40 … +125 °C
  • Available as relative pressure or absolute pressure transmitter

Standard pressure ranges TST 10… / 20…

Individual pressure ranges on request

Measuring rangeP(bar)1,01,62,02,54,06,010,016,02025
OverpressureP(bar)666101020204040100
Bursting pressureP(bar)999151530306060100
Measuring rangeP(bar)40601001602002504006001000
OverpressureP(bar)1002002004004007507508401200
Bursting pressureP(bar)1503003006006001000100010501500

Technical data

Pressure transmitter TST 10… / 20…
Electrical parametersTST 10…TST 20…
Output signal
Operating voltage UB
Permitted max. load RA
Recommended max. load resistor RL
4 … 20 mA (2- or 3-wire)
9 … 32 V DC
RA ? (UB – 9 V) / 20 mA
0 … 10 V DC (3-wire)
12 … 32 V DCRL > 5 k?
Response time (10 … 90 %)< 1 ms< 1 ms
Accuracy specifications
BFSL?± 0,15 % FS?± 0,15 % FS
Total error at RT

 

?± 0,50 % FS – including nonlinearity, hysteresis, zero point and full scale error
(according to IEC 61298-2).
Optionally available with increased measuring accuracy of ?± 0.25 % FS
Stability per year?± 0,10 % FS

Reference : tival-sensors.com

Download : Datasheet