Dwyer TFP-GV Series Gas Turbine Flow Meter

Description

Dwyer TFP-GV Series Gas Turbine Flow Meter utilizes a turbine wheel and electro-optical detection to convert flow rates into a linear 0 to 5 VDC output signal for recording and data logging. A power adapter or mating cable assembly is required for operation.

Gas Turbine Flow Meter sensors with electrical transmission output for remote indication of liquid flow rate. Dwyer Gas Turbine Flow Meter are suitable for a wide variety of industrial, commercial, and laboratory flow applications. A power adapter or mating cable assembly is required for operation.

Dwyer TFP-GV Series Features

  • Corrosion resistant PPS body
  • High repeatability with patented microturbine design
  • Design accurately measures flow rates with no zero drift and no required maintenance

Application

  • Industrial flow monitoring
  • Commercial systems
  • Laboratory equipment

Dwyer TFP-GV Series Specification

ServiceClean dry gases compatible with wetted materials.
Wetted MaterialsPPS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy±3% of FS.
Linearity±3% of FS.
Repeatability±0.5% of FS.
Temperature Limits41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C); Sensitivity: ±0.2% of FS per °C.
Pressure Limits40 psig (2.8 bar).
Process ConnectionCompression fitting
Power Requirements11.5 to 15 VDC.
Power Consumption35 mA @ 12 VDC.
Output Signal0 to 5 VDC; minimum 2.5 k? load.
Electrical ConnectionsFour-pin power and signal connector. A power adapter or mating cable required for operation.
Enclosure RatingIP10 (NEMA 1).
Weight0.16 lb (75 g).
Agency ApprovalsCE.