Kofloc 8500 Series Mass Flow Meter

Introduction

Kofloc 8500 Series Mass Flow Meter/meter driven by 24VDC power supply has been developed as a successor of the MODEL 8300. The viewpoint change function of the display unit and the pattern setting function are unique to this model, and noise resistance has been improved dramatically. A sister model with a detachable display and setting unit is also available.

  • The high-lift actuator allows this compact model to control a large flow rate.
  • Equipped with a display and setting unit, this model can be operated by the 24VDC power supply.
  • The RS232C/RS485 communication function and integration function are provided as standard equipment.
  • The 14-bit converter permits to display and operation in 4-1/2 digits.
  • Control of the flow rate of inflammable gas is possible because the heat generating part of the sensor is not exposed to the gas.
  • There are no limitations to the mounting position that may be employed.
  • In addition to the SV setting, five other patterns can be set.
  • Auto zero and auto close functions are also standard.

Kofloc 8500 Series Specification

ITEM8500MC/MM8550MC/MM
Flow range10SCCM?20SLM30SLM?100SLM
?N2 equivalent?20?/1ATM??freely selectable??freely selectable?
Sensor typeThermal sensor
Valve type?*1?Normally closed proportional solenoid valve
Control range?*1?2?100??F.S.?5?100??F.S.?
Response?*1??2sec?3sec
(within±2%F.S)(within±2%F.S.)
Accuracy±1.0%F.S.?25??±1.5%F.S.?25??
Temperature coefficient±0.1F.S./??15?35??±0.2F.S./??15?35??
Repeatability±0.5%F.S.
Operating differential
pressure
?*1?
F.S.?5SLM?50?300kPa?G?F.S.?50SLM?150?300kPa?G?
F.S.?5SLM?100?300kPa?G?F.S.?50SLM?200?300kPa?G?
Option?Medium differential pressure (MP), low differential pressure (LP) specifications are available
Allowable operating pressure?*1?500kPa?G? or less
Proof pressure980kPa?G?
Leak rate?1×10?8Pa??/s?excluding permeation of He?
Allowable operating temperature5?45?
Allowable operating humidity10?90?RH?No condensation allowed?
Materials of the gas contact partBody: SUS316
Valve seat :?FKM?option: CR or NBR?
Sealing :?FKM?option: CR or NBR?
Electrical connectionDsub half-pitch 20pin?DX10M?20S(HRS)
Flow rate setting signal0?5VDC?input impedance 100k? or more)
?*1?or 4?20mA?selectable
Flow rate output signal0?5VDC?external load resistance 250k? or more? or
4?20mA??external load resistance 300? or less?selectable
CommunicationRS232C?3 wire?or RS485?3 wire??selectable
Other functionsInstantaneous flow rate?integrated flow rate display ? 7-segment 4-digit LED
display accuracy ±1%?integrated display 0000?9999MAX?,
Alarm output?NPN open collector output 2 points
Max DC35V?50mA?, pattern setting?5 pattern? function
Required power supply24VDC±10%?ripple 5%? current consumption 300mA max
JointStandard?1/4F900?9/16-18UNF?Standard?3/8F900?9/16?18UNF?
?Main unit bore?Option 1/8F900, 1/4UJR,Option 1/2F900, 3/8UJR,
?Rc1/4 etc.Rc3/8 etc.
WeightApprox. 1200gApprox. 1500g

(*1)Only for the mass flow controller.