Kofloc VN Compact Electromagnetic Flow meter

Kofloc VN Compact Electromagnetic Flow Sensor Series is an electromagnetic flow sensor designed for small pipe diameter and low flow. Electromagnetic flow sensor without moving parts suitable for use in machines. With the absence of moving parts, there is less failure due to its contaminants, Low-pressure loss, No straight pipe required, compact design, and easy to installation.

Kofloc VN Compact Electromagnetic

Features

  • Electromagnetic flow sensor without moving parts suitable for use in machines.
  • With absence of moving parts, there is less failure due to its contaminants.
  • Low-pressure loss
  • No straight pipe required, compact design, and easy to install.

Specification

ModelVN05RVN10RVN20R
Nominal Diameters5mm10mm20mm
Accuracy-Guaranteed Flow Range0.05?1L/min0.5?10L/min3.0?60L/min
Maximum Operating Flow Rate3L/min25L/min100L/min
Low Flow Cutoff0.025L/min0.25L/min1.5L/min
Accuracy (Liquid Temp. At 25?)Frequency Pulse±2.5%RS (20% ~ 100% of maximum flow rate) ±0.5%FS (5% ~ 20% of maximum flow rate) *1
Unit Pulse±2.0%RS (20% ~ 100% of maximum flow rate) ±0.4%FS (5% ~ 20% of maximum flow rate) *1
Type of FluidConductive fluid that does not corrode the material contacting to fluid (ex. cold/hot water)
Fluid Conductivity Range50?S/cm or more
Fluid Temperature Range0?+60? (No freezing)
Ambient Temperature / HumidityTemperature: -20?+60? Humidity: 35?85?RH (No condensation)
Storage Ambient Temperature Range-20?+70?
Working Pressure1MPa or less
Pressure Loss20kPa or less
Output 1 *3Spec. of OutputNPN open collector Current capacity: 20mA DC or less / Voltage: 30V DC or less /
ON-time residual voltage: 1V or less
Minimum pulse ON-time 2.5 ms (at 200 Hz frequency pulse) Duty ratio: 50%
Frequency Pulse *2Standard 200.0Hz (Settable in steps of 0.1Hz between 20 and 400Hz upon delivery)
Note: When connecting ASI-100, select 200.0 Hz for output 1.
Unit Pulse0.001L/P (Standard)0.01L/P (Standard)0.1L/P (Standard)
Alarm *4Selectable between Normal Open (Standard) and Normal Close
Details of alarm (Excitation error / Memory error / Low source voltage / Dry moisture /
Excessive fluid noise / Excessive flow rate / Reverse flow)
SwitchSelectable between Normal Open (Standard) and Normal Close
Output 2 *3Spec. of OutputSame as Output 1
Unit PulseSame as Output 1
Alarm *4Same as Output 1
Note: When connecting ASI-100, select Alarm for output 2
SwitchSame as Output 1
Response *363? response Dampling time: 2s (Standard) Settable in steps of 1s from 1~99s upon delivery
CableCable length: Approx. 500mm 4 core AWG28 Outer diameter: ?2.8 with a shield
LED DisplayOne LED display in the main body
Green: Flow rate display in 3-step speed
Red: NG status is displayed with number of blinks
Installation PositionFree (Air intrusion shall be avoided.)
Piping ConnectionR1/4R1/2R1
Protection LevelIndoor use (Equivalent to IP65.)
Power Supply *512?24V DC±10%
Consumption Current100mA DC or less
WeightApprox. 190 gApprox. 190 gApprox. 290 g
Wetted MaterialsBody CasePPS
ElectrodeSUS316L
Earth RingSUS316
O-RingFKM
  1. Accuracy is guaranteed value of average value accumulated for 240s.
  2. Indicates the frequency at the maximum guaranteed flow rate.
  3. For the set value and choice of Output 1 and Output 2, all are factory setting. The setting cannot be changed after installation.
  4. Alarm is selectable only either one of Output 1 or Output 2.
  5. Using isolated power supply and connecting one power supply device per VN flow sensor are recommended

Download Datasheet: Kofloc VN Electromagnetic Flow Meter

Other Articles:

 

author

Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Similar Posts