KEP meter Intellect-69PM2 (INT69PM2) Process Monitor

Description

The KEP meter  Intellect-69PM2 is a process monitor that accepts analog signal inputs and features 41/2 digits of bright, 7-segment LED displays. The unit can be field programmed to accept 0-20mA, 4-20mA, 0-5V, 0-10V, or 1-5V signals. Two assignable set points are standard for high/low alarm outputs.

The high and low scaling settings (-9999 to 49999) are programmable from the front panel. By pressing the “view” button, the unit will display process reading, peak, or valley. Press the lock button once to freeze the display, and press it again to resume normal operation.

Press the lock button 4 times quickly to enter the lock code for panel lockout. RS-232, RS-422, and 4-20mA analog out are available options for interfacing to a host computer or strip chart recorder. Featuring 41/2 digits of bright, 7-segment LED displays, the KEP meter Intellect-69PM2 is a process monitor that accepts analog signal inputs. The unit can be field programmed to accept 0-20mA, 4-20mA, 0-5V, 0-10V or 1-5V signals.

Feature

  • Analog Input 0-20 mA, 4-20 mA 0-5V, 0-10V or 1-5V
  • Display Rate, Pressure, Level, Temperature, Watts, etc., Peak & Valley
  • Calibration, High and Low Values (-9999 to 49999) Fully Programmable Through Keypad
  • NEMA 4X / IP65 Front
  • +24V Output for Peripherals
  • 16 Bit A/D Resolution
  • 2 Form C SPDT Relays (optional)
  • 2 Levels of Operator Password Lockout

Application

  • Any process monitoring application where two set points and scaling are needed.

Specification

  • Display 41/2 digit, .55” high, 7 segments, red-orange, LED.
  • Input Power
    • 110, 220 VAC ± 15% or 12 to 24VDC.
    • Current:300 max. mA DC or 10.0 VA (10W) at rated AC voltage.
  • Output Power (AC powered units only) + 24VDC @ 50mA regulated ±5%. (100 mA available on request)
  • Temperature Operating: +32°F (0°C) to +130°F (+54°C).
  • Storage: -40°F (-40°C) to +200°F (93°C).
  • Memory EEPROM stores data for ten years if power is lost.
  • Reset Front Panel: resets displayed value and control outputs.
  • Control Outputs Standard:
    • Open collector sinks 250mA from 30VDC when active.
    • Optional: 2 each Form C SPDT 5 Amp @ 120/240 VAC or 28 VDC.
  • Input Linear 0-20mA, 4-20mA, 0-5V, 0-10V or 1-5V selectable from the front panel.
  • Calibration The unit does all of the calibrations internally. There are no potentiometers to adjust and the unit never needs to be removed from the case or panel.
  • Set Points
    • Two control setpoints are provided.
    • The unit comes standard with two open collector control outputs. Two 5 Amp, Form C relays are optional.
    • The outputs have a programmable alarm range from -9999 to 49999 with hysteresis.
  • Process Display Updates 4 times per second, accurate to 4.5 digits.
  • Programming Decimal points, Scaling from -9999 to 49999, setpoints, input type, and security lock code are all programmable from the front panel.
  • Housing Standard 1/8 DIN, high impact ABS plastic case (NEMA 4X/IP65 front panel).
  • Shipping Weight 2 lbs.
  • Overvoltage Protection 50 V
  • Over-current Protection 50 mA
  • Temperature Stability Will not drift more than 10 parts per million per °C from 0°C to 54°C
  • Accuracy 1% (5 V inputs .16%)
  • Listing CE Compliant, CSA (File No. LR91109), NRTL/C pending

Data Sheet: Datasheet Intellect-int69pm2

Reference: kepmeters.com