Bamo Variable area flow metre G6/G5-250

The flow rate is indicated on the front (magnetic coupling of the diver with the external indicator). The short distance of 250 mm between flanges allows an installation in reduced space. In addition, no straight pipe distances upstream and downstream are required.

Bamo Variable area flow metre G6/G5-250
Bamo Variable area flow meter G6/G5-250

Bamo Variable area flow meter G6/G5-250

  • Magnetic movement transmission
  • Scales: 2.5 to 63000 L/h (water)
  • Float: Stainless steel 316 L or PTFE
  • Threaded or flange connections
  • Options:
  • LCD digital display for flow rate and totalization
  • Hart protocol, 4-20 mA output
  • 1 or 2 adjustable alarm contacts
  • ATEX certification,
  • EEx ia IIC T6 / EEx d IIB T4

Benefits & Features Bamo Variable area flow metre G6/G5-250

  • Scale range: 1 to 10
  • Analogical scale length: 80 mm
  • Accuracy: +/- 1.5% full scale (standard)
  • Repeatability: 0.5% full scale
  • Maximal pressure: 40 bar
  • Temperature limits:

    • -10 … +150°C without alarm contacts
    • -10 … +100°C with alarm contacts
    • -30 … +300°C high temperature version (with and without alarm contacts)
  • Process connections: Flanges PN 16 UNI 2223/29 (standard); threads BSP, NPT, Triclamp
  • Wetted parts: Stainless steel 316 L, PTFE – on request: Titanium, Hastelloy C
  • Display housing: Cast aluminium, epoxy painted RAL 7001
  • Protection: IP 67
  • OPTIONS: Inductive contacts (adjustable all along the scale) with 8 V CC power supply

Indicator with transmitter

  • Scale range: 1 to 10
  • Analogical scale length: 80 mm
  • Accuracy: +/- 1% full scale (standard)
  • Repeatability: 0.5% full scale
  • Programmable display: LCD, 8 digits (flow rate, %, totalization)
  • Response time: < 0.5s (only the electronic)
  • Analogical output: 4-20 mA, 2 wires
  • Hart protocol transmission: optional
  • Main power: 24 V DC +/-10%
  • Alarm contacts: optional, 1 or 2 adjustable contacts
  • Maximal pressure: 40 bar
  • Temperature limits:

    • -10 … +90°C without alarm contacts
    • -10 … +90°C with alarm contacts
    • -30 … +300°C high temperature version (with and without alarm contacts)
  • Process connections: Flanges PN 16 UNI 2223/29 (standard); threads BSP, NPT, Triclamp
  • Wetted parts: Stainless steel 316 L, PTFE – on request: Titanium, Hastelloy C
  • Display housing: Cast aluminium, epoxy painted RAL 7001
  • Protection: IP 67

OPTIONS:

  • ATEX Certification EEx ia IIC T6 (Intrinsically safe)
  • ATEX Certification EEx d IIB T4 (Explosion proof enclosure)

Source : www.bamo.fr