Simplex – Addressable Peripheral Devices

Simplex addressable modules provide individual identification, monitoring, and control for conventional devices, such as flow monitors, and systems such as elevators and building controls.

Using modules to create an integrated system allows viewing and management of the entire fire protection system with graphical management consoles and across remote access solutions like SafeLINC. With a unified picture, users can manage the life safety system more easily and respond to emergencies more effectively.

TrueAlarm I/O Modules and Peripherals

You can add addressability to conventional devices, such as flow switches with Simplex addressable modules.

  • Easily interface other devices and systems to your Simplex addressable fire alarm control unit
  • Provide point identification, monitoring, and control to conventional devices and external systems
  • Power and communication isolation to increase system integrity

Simplex IDNet addressable modules provide addressability, point monitoring, and control to conventional devices and other systems like elevators, HVAC, and sprinklers. Simplex products include a wide range of innovative addressable modules, including multi-point modules, modules that permit individual reporting from flow and tamper switches on the same circuit and isolator modules that protect power wiring from short circuits and ground faults.

TrueAlarm IO Modules and Peripherals
TrueAlarm IO Modules and Peripherals

Features TrueAlarm I/O Modules and Peripherals

  • Individual addressable modules (IAMs):Receiving both power and communications from a two-wire circuit, IAMs provide location-specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector cont
  • The Security Monitor IAM:Get location-specific addressability for up to five initiating devices, such as window or door magnet switch contacts or other similar security devices.
  • IDNet/MAPNET II Monitor ZAMs:Users can enable a single addressable point to monitor a conventional initiating device circuit (IDC) populated with 2-wire or 4-wire initiating devices.
  • IDNet Relay IAMs:These modules allow the fire alarm control unit to control a remotely-located Form “C” contact. Typical applications include elevator capture and control of HVAC components, such as pressurization fans and dampers.
  • The Single Address Six Point Module:This module allows the IDNet communication channel to monitor four T-sense input circuits and control two output relays from a single compact module requiring a single address.
  • Communications Isolators:These devices provide IDNet communication and power isolation, improving installation convenience and increasing system integrity.
    Benefits

 

Read More Article :

 

Similar Posts