General Information
APG TLS Series Dual Point Cable Suspended Float Switches are dual-point switches that provide built-in hysteresis for better pump control. The switch operating levels are easily adjustable based on the cable weight location, and the floats are especially suited for use in waste water and sewage applications with low specific gravity.
Built-in hysteresis provides high and low level control. The TLS series cable switches are dual point switches with built in hysteresis to provide high and low level control that won’t wear out your pumps with frequent on/off cycles.
Built-in Hysteresis
With switch action at a high and a low level, the TLS provides level control that won’t wear out your pumps with frequent on/off cycles.
Wide Angle Action
The choose between 11″ – 39″, 13″ – 157″ or a 28° switching differential and adjustable cable weight of the TLS provide customizable High and Low level settings.
Versatile Applications
Polypropylene or ABS Resin housing, PVC jacketed cable, and up to 65 ft (20 m) of cable allow the TLS to go a lot of places other low-cost float switches can’t.
APG TLS Series Features
- High or Low Level control
- Highly chemical resistant
- Proven reliability in operation
- Not sensitive to rotation • Cable weight
Specification
Performance | |
Control Differential | TLS-6A/B: 11″-39″ (0.27 – 1m) |
TLS-8A/B: 13″-157″ (0.33 – 4m) | |
TLS-6-B: 28° ± 2° | |
Electrical | |
Voltage | TLS-6A/B: Max. 300 VAC/VDC, 50/60 Hz |
TLS-8A/B: Max. 300 VAC/VDC, 50/60 Hz | |
TLS-6-B: 125/250 VAC, 50/60 Hz | |
Current Rating | TLS-6A/B: Max. 0.5 AC/DC |
TLS-8A/B: Max. 0.5 AC/DC | |
TLS-6-B: Max. 10A / 250 VAC | |
Connectivity | |
Switch Output | NO or NC |
Environmental | |
Max. Liquid Temperature | TLS-6A/B: -10° – 50°C (14° – 122°F) |
TLS-8A/B: -10° – 50°C (14° – 122°F) | |
TLS-8A/B -T: -10° – 70°C (14° – 158°F) | |
TLS-6-B: 0° – 60° C (32° – 140°F) | |
Physical | |
Housing | TLS-6A/B: Polypropylene with ABS Resin cap |
TLS-8A/B: ABS Resin | |
TLS-6-B: Polypropylene | |
Cable | TLS-6A/B: 2/c 0.5mm2 (~20 AWG) |
TLS-8A/B: 2/c 0.75mm2 (~18 AWG) | |
TLS-6-B: 2/c 1.25mm2 (~16AWG) | |
All with PVC jacket | |
Cable Lengths | 6m (20 ft.) Standard |
Other lengths available: 12m (40 ft.), 18m (60 ft.) |
Download Data Sheet: Dual Point Cable Suspended Float Switch TLS
Ref: apgsensors.com
Other Articles:
- Hengesbach Level Module for Installation in Level Probes Tyoe NM
- Takuwa Water Level Gauge Sensor
- Mac3 Float Level Switch
- Hengesbach Level Module NC1 Series
- Mechatronics Dizzi Fluid Level Sensor
- Parker JF-32 Level Switch
- Delavan Captrol Integral 500 Point Level Measurement
- Omnitrol 610/710 Float Switch Type
- APG FLX Series Hazardous Location Multi-Point Level Switch
- APG FL Series Stem Mounted Multi-Point Level Switch