CAMON Metal Tube Float Flow Meter

Metal tube float flow meter adopts variable area measuring principle to measure liquid and gas of multiple directions. Metal tube float flow meter adopts variable area measuring principle to measure liquid and gas of multiple directions. It is widely applied in industries such as petro,chemical,poer supply,food,pharmcy and water treatment,etc.

Camon Metal Tube Float Flow Meter
Camon Metal Tube Float Flow Meter

INDICATOR INDTODUCTION

M1 Indicator

1.Introduced a pair of coupled magnet to realize flow indicating and transmission of electric signal.

2.Introduced the newest ESK signal transmitter with 4~20mA output.

3.Compatible with HART agreement.

4.Equipped with upper and lower limit alarming switch.

5.Intrinsic safety structure design with ExibIICT5 and EXiaIICT1-T4 explosion-proof mark.

M2 Indicator

1.Through cam board transmitting non-linear magnetic float to be linear current value and indicated by indicator needle on the dail.

2.Equipped with 4~20mA output angular rotation transmitter of KSW1.

M6 Indicator

1.Adopts magnetic snesor to response drift of magnetic float. Output 4~20mA amd digital display without magnetic lag.

2.Digital display instantaneous flow and accumulative flow.

3.Compatible with HART agreement.

4.Explosion supression standard with ExdIICT4-T6.

Main Parameter

Measuring Rangewater(20?):.5~180,000L/h

air(20?,101325 Pa):0.07~1800m3/h

Range RatioDN15~100: 10:1

DN125~150: 5:1

Accuracy2.5 / 1.5
Max.Operation PressureDN15~50: 4.0 MPa

DN80~150: 1.6 MPa

Jacket Pressure1.6 MPa
Medium Temperature-80~+200?

0~80?(non-corrosive model)

Environment Temperature-25~+120?

-20~+70?(electric remote transmission model)

-20~+60?(LCD display model)

Medium ViscosityDN15?5mPa.s

DN(25~150)?250mPa.s

Connection Typeflange, can OEM according to the specific requirement
ProtectionIP65
Electric Remote Transmission24(1±10%)VDC, 4~20mADC or 2-wire(HART for option),RS485
Linear1%
Load Resistance?500?(24VDC)
Temperature Effection<±0.05%F.S/?
Power Consumption<1W
CableRVVP3×28/0.15
Limit AlarmRVVP3×2Voltage:24(1±10%)VDC

power consumption:<1W

operation temperature:-25~+65?

max.load current: 50mA8/0.15

Instrinsic Explosion-proofEXibIICT5 / ExiaIICT1-T4
Explosion SuppressionExdIICT4-T6

Sources: .a-instrument.com/flow-meter/metal-tube-flow-meter/metal-tube-float-flow-meter.html