Ryuki FLO-70 Rotameter Special Assembly

General Descriptions

Ryuki FLO-70 Rotameter Special Assembly is a high-precision area-type flow meter that can read the instantaneous flow rates of various liquids and gases directly from the scale indicated by the float. The flow rate can be adjusted freely by adjusting the valve. Used for general equipment and panel mounting in academic research institutions and other industries.

Ryuki FLO-70 Rotameter Special Assembly Model number

FLO-L70 type (with a thermometer, pressure gauge, valve, base)
FLO-L70 type (with a thermometer, 2 stations)
FLO-L70 type (special assembly)

Ryuki FLO-70 Rotameter Special Assembly General specifications

Measuring fluidLiquid (water, cooling water, transparent liquid)
Gas (air, nitrogen, argon, carbon dioxide, etc.)
Scale range10: 1
Flow rateLiquid 7 ? 70L / min
Gas 90-900NL / min
Body materialBrass (BS), SUS304, SS, etc.
Tapered tube materialHard glass
Float materialLiquid SUS304 SUS316
Gaseous aluminum
PackingNBR, CR (neoprene), Viton
Connection methodRc connection
Port sizeRefer to the measurement range table
Flow rate accuracyWithin ± 2% FS
Mounting directionVertical direction
Flow directionPlease specify by model code
Maximum working pressure0.7MPa
Maximum operating temperature80 ? (Varies depending on the material)
Thermal shock 50 ? or less
External dimensionsRefer to the measurement range table

Measurement range (Please contact us for other products as well.)

Classification NoFlow rate displayFlow rate displayPort sizeExternal dimensions mm
H2O (L / min)AIR (NL / min)Rc
00.001 to 0.010.01-0.11 / 4B345
10.05-0.50.5-51 / 4B345
20.2-2.05-501 / 4B345
Three0.5-515-1501 / 4B345
Four1-1020-2001 / 2B345
Five2-2040-4003 / 4B475
64-4060-6001B555
77-7090-9001B565
  • We will manufacture after confirming the fluid name, density, viscosity, pressure, temperature, flow range, connection standard, body material, packing material, etc.
  • For liquid measurement (Float: SUS304, etc.)
    • Density = 1.0 g / cm3 and viscosity = 1 cP as standard.
  • For gas measurement (Float: Aluminum etc.)
    • AIR 20 ° C is flown, and the flow rate value is converted to the standard state AIR, 0 ° C 1 atm (atmospheric pressure). (Unit: NL / min)
      *Products are converted to standard conditions (atmospheric pressure 20 ° C) upon request. (Unit: SL / min)

Model code (please tell us when making an inquiry)

Flow directionfluidClassificationWetted materialvalvePacking materialThermometer (t) / Pressure gauge (p)Flow range, operating temperature, pressure
FLO-L70-?-?-0 ?-T-V-P-?
A [AIR]0BSN [None]1 [NBR]0-None
2W [Wed]1SUS304U [top]2 [CR (neoprene)]1-pt available
[Lower horizontal (right) ? Upper horizontal (left)]
Three2SSD [bottom]3 [FKM Viton]2-t available
[Bottom side (left) ? Topside (right)]
Four33-p available
[Behind the back ? Back]
4Notices

* Details of the flow range, operating pressure, and temperature are required.

Please fill in if the fluid is other than air or water.

Consult us for fittings such as hose nipples, half unions, and elbow unions as accessories.

Model code entry example

  • Example ? FLO-L70-3-A-02-TBS-VU-P1-1 Flow rate range 3 to 30NL / min, temperature 20 ?, pressure 0.101MPa
    Accessories: Not required Product image ?
  • Example ? FLO-L70-3-A-03-TBS-V0-P1-2-2 series flow rate range 5 to 20NL / min, temperature 20 ° C, pressure 0.101MPa (A)
  • FLO-L70-3-A-04-TBS-VU-P1-1-2 series flow rate range 20 ~ 200L / min, temperature 20 ?, pressure 0.101MPa (A)
    Accessories: Not required Product image ??