Speedy Pulsar Contacting doppler flow velocity sensor

Description

Speedy is a steamlined, easy to fit liquid velocity sensor for use in channels, pipes or sections where no Primary Measurement Device (PMD) exists.

Pulsarโ€™s Speedy velocity sensor communicates digitally and is designed to connect to Pulsarโ€™s FlowCERT open channel flow monitor via FlowCERTโ€™s on-board RS485, it provides the velocity measurement for velocity x head calculations of flow rate where no primary measurement device exists. Speedy can be mounted up to 250m from the FlowCERT controller. Speedy is available as a โ€œwedgeโ€ sensor with a stainless steel base plate or as a pipe mounted sensor.

Speedy operates with one of the following Pulsar controllers:

    • Velocity Interface
      2 relays
      1x 4-20mA output
    • FlowCERT
      5 relays
      2x 4-20mA outputs
      Requires a Pulsar transducer
    • Ultimate
      8 relays standard (expandable)
      2x 4-20mA outputs standard (expandable)
      Two channel system (expandable
      Requires a level transducer

Features

  • Streamlined, easy to fit sensor
  • In channels, pipes where no PMD is fitted
  • Wedge base mount or pipe mount option
  • Reliable proven and easy set up

Technical Specification

Physical

Constructions:Wedge sensor: installation on channel bottom
Pipe sensor: installation using nozzle and cutting ring joint in pipes
Construction material/description:Wedge sensor: Polyurethane, stainless steel 1.4571, PVDF
PA pipe sensor: stainless steel 1.4571, polyurethane, FEP coated cable
Sensor body weight:Nominal 1.5kg (3.3lbs)
Cable length:Up to 50m (164ft)
Cable types:LiC11Y 2ร—1.5 + 1x2x0.34
Cable diameter:8.4mm ยฑ 0.25mm (0.33in ยฑ 0.01in)

Environmental

IP rating:IP68
Operating temperature:-20ยฐC to +50ยฐC (-4ยฐF to +122ยฐF)
Storage temperature:-30ยฐC to +70ยฐC (-22ยฐF to +158ยฐF)
Operating pressure:Max. 4bar (58psi)

Performance

Accuracy/Repeability:1% of the measured range or ยฑ0.03m/s (ยฑ0.1ft/s)
Resolution:3mm/sec
Measurement range:-6m/s to +6m/s (-20ft/s to +20ft/s)
Measurement principle:Doppler (flow velocity). Flow velocity sensor with v measurement using Doppler principle and temperature measurement to compensate temperature effects on speed of sound.
Measurement frequency:1MHz
Zero point drift:0 โ€“ absolutely stable zero point
Sonic lobe:ยฑ5 degrees
Temperature measurement:-20ยบC to +60ยบC ยฑ0.5ยบC (-4ยฐF to +140ยฐF ยฑ 32.9ยฐF)