Description
Speedy is a steamlined, easy to fit liquid velocity sensor for use in channels, pipes or sections where no Primary Measurement Device (PMD) exists.
Pulsarโs Speedy velocity sensor communicates digitally and is designed to connect to Pulsarโs FlowCERT open channel flow monitor via FlowCERTโs on-board RS485, it provides the velocity measurement for velocity x head calculations of flow rate where no primary measurement device exists. Speedy can be mounted up to 250m from the FlowCERT controller. Speedy is available as a โwedgeโ sensor with a stainless steel base plate or as a pipe mounted sensor.
Speedy operates with one of the following Pulsar controllers:
- Velocity Interface
2 relays
1x 4-20mA output - FlowCERT
5 relays
2x 4-20mA outputs
Requires a Pulsar transducer - Ultimate
8 relays standard (expandable)
2x 4-20mA outputs standard (expandable)
Two channel system (expandable
Requires a level transducer
- Velocity Interface
Features
- Streamlined, easy to fit sensor
- In channels, pipes where no PMD is fitted
- Wedge base mount or pipe mount option
- Reliable proven and easy set up
Technical Specification
Physical
Constructions: | Wedge sensor: installation on channel bottom |
Pipe sensor: installation using nozzle and cutting ring joint in pipes | |
Construction material/description: | Wedge sensor: Polyurethane, stainless steel 1.4571, PVDF |
PA pipe sensor: stainless steel 1.4571, polyurethane, FEP coated cable | |
Sensor body weight: | Nominal 1.5kg (3.3lbs) |
Cable length: | Up to 50m (164ft) |
Cable types: | LiC11Y 2ร1.5 + 1x2x0.34 |
Cable diameter: | 8.4mm ยฑ 0.25mm (0.33in ยฑ 0.01in) |
Environmental
IP rating: | IP68 |
Operating temperature: | -20ยฐC to +50ยฐC (-4ยฐF to +122ยฐF) |
Storage temperature: | -30ยฐC to +70ยฐC (-22ยฐF to +158ยฐF) |
Operating pressure: | Max. 4bar (58psi) |
Performance
Accuracy/Repeability: | 1% of the measured range or ยฑ0.03m/s (ยฑ0.1ft/s) |
Resolution: | 3mm/sec |
Measurement range: | -6m/s to +6m/s (-20ft/s to +20ft/s) |
Measurement principle: | Doppler (flow velocity). Flow velocity sensor with v measurement using Doppler principle and temperature measurement to compensate temperature effects on speed of sound. |
Measurement frequency: | 1MHz |
Zero point drift: | 0 โ absolutely stable zero point |
Sonic lobe: | ยฑ5 degrees |
Temperature measurement: | -20ยบC to +60ยบC ยฑ0.5ยบC (-4ยฐF to +140ยฐF ยฑ 32.9ยฐF) |
Reference : www.pulsar-pm.com