Aquaread The LeveLine-Mini Water Meter

Aquaread The LeveLine-Mini Water Meter is a water level and temperature measuring sensor that has been specifically designed to reduce your monitoring costs. It is constructed using titanium and features sensitive pressure and temperature sensors.

Aquaread The LeveLine-Mini Water Meter Features

  • High-quality titanium body
  • Features a Delrin nose cone
  • Uses the same Piezoresistive pressure sensor found for highest accuracy
  • Impressive accuracy of 0.1% FS
  • The sensor can log as fast as 10 times per second
  • Cable is hard wired into the sensor, various lengths available to suit every deployment
  • SDI-12 / Modbus output as standard
  • Sensors come with a 2 year warranty

Aquaread The LeveLine-Mini Water Meter Specifications

General

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Temperature ranges Operational: -20-80° C (-4-176° F) Operational: -20-80° C (-4-176° F) Operational: -20-80° C (-4-176° F) Operational: -20-80° C (-4-176° F) Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F) Storage: -40-80° C (-40-176° F) Storage: -40-80° C (-40-176° F) Storage: -40-80° C (-40-176° F) Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F) Compensated: -20-80° C (-4-176° F) Compensated: -20-80° C (-4-176° F) Compensated: -20-80° C (-4-176° F) Compensated: -20-80° C (-4-176° F)
Diameter 22.2mm (0.875 in) 22.2mm (0.875 in) 22.2mm (0.875 in) 22mm 22mm
Length 186mm (7.32 in) 186mm (7.32 in) 87mm (3.43 in) 260mm 146mm
Weight 150g (5.3oz) 160g (5.6oz) 120g (4.2oz) 250g 210g
Materials Titanium body, Delrin nose cone Stainless Steel body, Delrin nose cone Stainless Steel body, Delrin nose cone Titanium body, Delrin nose cone Titanium body, Delrin nose cone
Output options Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary
Battery type & life 3.6V lithium; up to 10 years (see note 1) 3.6V lithium; up to 10 years (see note 1) N/A 3.6V lithium; up to 10 years (see note 1) N/A
External power 6 – 30 VDC 6 – 30 VDC 6 – 30 VDC 6 – 24 VDC 6 – 24 VDC

Aquaread The LeveLine-Mini Water Meter Memory

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Size 8.0 MB 2.0 MB N/A 8.0 MB N/A
Data records 500 150 N/A 500 N/A
Log types Linear, Event & User-Selectable Linear, Event & User-Selectable N/A Linear, Event & User-Selectable Schedule with Future N/A
Schedule with Future Start, Future Stop, Schedule with Future Start, Future Stop, Start, Future Stop, Deploy Start and Real Time View
Deploy Start and Real Time View Deploy Start and Real Time View
Fastest logging rate & Modbus rate 10 per second 1 per minute (logging) 10 per second (Modbus Rate) 1 per second 1 per second
5 per second (Modbus)
Fastest SDI-12 output rate 1 per second 1 per second 1 per second 1 per second 1 per second
Real-time clock Accurate to 1 second/24-hr period (± 6 minutes/year) Accurate to 1 second/24-hr period (± 6 minutes/year) N/A Accurate to 1 second/24-hr period (± 6 minutes/year) N/A

Sensor

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Type / Material Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic
Range (Absolute) 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) 0 to 16.7 psi; 0 to 1.15 bar 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Range (Gauge) 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) N/A N/A 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Maximum pressure Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range
Accuracy (FS) (see note 3) ±0.05% FS ±0.1% FS ±0.05% FS ±0.05% FS ±0.05% FS
Accuracy (FS) (See note 2) ±0.1% FS ±0.2% FS ±0.1% FS ±0.1% FS ±0.1% FS
Resolution 0.005% FS or 1mm whichever is greater 0.1mb 0.005% FS or 1mm whichever is greater 0.002% FS or 1mm whichever is greater 0.002% FS or 1mm whichever is greater
Units of measure Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink

Electrical Conductivity

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Range N/A N/A N/A 0 – 200mS/cm (0 – 200,000µS/cm) 0 – 200mS/cm (0 – 200,000µS/cm)
Resolution N/A N/A N/A 1µS 1µS
Accuracy N/A N/A N/A ± 1% reading or ±1µS whichever is greater (see note 5) ± 1% reading or ±1µS whichever is greater (see note 5)

Salinity (note 4)

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Range N/A N/A N/A 0 – 70 PSU / 0 – 70 ppt (g/Kg) 0 – 70 PSU / 0 – 70 ppt (g/Kg)
Resolution N/A N/A N/A 0.01PSU / 0.01 ppt 0.01PSU / 0.01 ppt
Accuracy N/A N/A N/A ±1% reading or ± 0.1 unit if greater ±1% reading or ± 0.1 unit if greater

Temperature Sensor

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Accuracy Resolution ±0.1° C ±0.1° C ±0.1° C ±0.1° C; 0.01° C ±0.1° C; 0.01° C
0.01° C 0.01° C 0.01° C
Units of measure Celsius Celsius Celsius Celsius (fahrenheit available in LeveLink) Celsius (fahrenheit available in LeveLink)

Warranty

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Standard N/A N/A N/A 2 years 2 years
Extended N/A N/A N/A Options Available Options Available
  • Dependent on logging rate.
  • Across factory-calibrated pressure range at a constant temperature.
  • Across factory-calibrated pressure and temperature ranges.
  • Readings calculated from EC and temperature values. 5) At the calibration point at 25°C

Reference : aquaread.com