Bamo NIVAPRESS SGE-25 Hydrostatic Level Transmitter is simplified by the use of a fastening system, such as a suspension clip (a) or/and a BJSC holder (b). The probe can hang freely at the end of the cable or lie down at the bottom of the tank.
The junction box BJSC with pressure compensation, allows to fix the sensor and ensures the balancing of atmospheric pressure through an integrated vent on the front of the housing. It significantly reduces the risk of entry of dust and moisture.
It is also recommended to extend the life of the probe cable. A cable extension could be done with a standard cable. For large cable distances it is necessary to use the box junction BPS102 (wall mount) with surge protection device.
Bamo NIVAPRESS SGE-25 Features
- Measuring ranges up to 500 m H?O
- Probe: AISI 316 L
- Diaphragm: Hastelloy
- Protection against overloads
- ATEX or DNV certification
Application
Hydrostatic level transmitter NIVAPRESS SGE-25 is convenient for measuring clear liquids, stored in opened tanks and wells. It is recommended for monitoring and control of submersible pumps.
Bamo NIVAPRESS SGE-25 Specification
Measuring ranges | 1 m WC | 4 m WC | 0…10 / 500 m WC |
Acceptable override | 40 times F.S. | 25 times F.S. | 10 times F.S. |
(700 m WC max.) | |||
Accuracy | 0.60% | 0.30% | 0.20% |
Temperature error | 0.3 %/ 10 °C (average | 0.3 %/ 10 °C (average | 0.2 %/ 10 °C (average) |
0.4 %/ 10 °C (max.) | 0.4 %/ 10 °C (max.) | 0.3 %/ 10 °C (max.) | |
Long time stability | 0.1 % or 1 cm WC/ year | 0.1 % or 1 cm WC/ year | 0.1 % or 1 cm WC/ year |
Hysteresis | 0.05% | 0.05% | 0.05% |
Temperature compensation | 0… +40 °C | 0… +40 °C | 0… +40 °C |
Operating temperature | -25 … +40 °C | -25 … +40 °C | -25 … +40 °C |
Output signal/ supply | Analogue 4-20 mA 2-wire; Supply: 8 to 36 V DC (9 to 28 V DC for EEx version) | Analogue 4-20 mA 2-wire; Supply: 8 to 36 V DC (9 to 28 V DC for EEx version) | Analogue 4-20 mA 2-wire; Supply: 8 to 36 V DC (9 to 28 V DC for EEx version) |
Protection | IP68 | IP68 | IP68 |
Body | AISI 316 L | AISI 316 L | AISI 316 L |
Diaphragm | Hastelloy C276 | Hastelloy C276 | Hastelloy C276 |
Cable | PUR (polyurethane) | PUR (polyurethane) | PUR (polyurethane) |
Options | |||
Version i.s. (4-20 mA) | II 1G EEx ia IIC T4 / T5 / T6 | II 1G EEx ia IIC T4 / T5 / T6 | II 1G EEx ia IIC T4 / T5 / T6 |
Version 0-10 V | 0-10 V 3-wire; Supply: 15 to 30 V DC; No anti-surge protection; Not available in EEx version | 0-10 V 3-wire; Supply: 15 to 30 V DC; No anti-surge protection; Not available in EEx version | 0-10 V 3-wire; Supply: 15 to 30 V DC; No anti-surge protection; Not available in EEx version |
Marine Certification (MR) | DNV GL | DNV GL | DNV GL |
Temperature compensation | -10 … +70 °C | -10 … +70 °C | -10 … +70 °C |
Cable | PTFE | PTFE | PTFE |
Download Data Sheet: Hydrostatic Level Transmitter NIVAPRESS SGE-25
Ref: bamo.eu
Other Article:
- Aplisens Hydrostatic Level Probes SGE-25 and SGE-16
- Flux Drum Pump with Mechanical Seal F 430 / FP 430
- Bamo MEMPRO Hydrostatic Level Transmitter