Honda HL2000 Ultrasonic Level Meter

Description of Honda HL2000 Ultrasonic Level Meter

Honda HL2000 ultrasonic signal has the characteristic that it reflects where the density changes. The submerged sensor transmits an ultrasonic signal, and then the signal reflects at the interface inside the tank. Some parts of the signal penetrate into the sludge and it also reflects at the rake or bottom of the tank.

Ultrasonic signal transfers in the unclear water. There is no need to contact the measuring object (sludge), the measurement can be done without sinking the sensor deep into the tank.

Interface Honda HL2000 Ultrasonic Level Meter
Interface Honda HL2000 Ultrasonic Level Meter

Features of Honda HL2000 Ultrasonic Level Meter

  • A wide range of distances can be measured from 0.4 to 10 m from the sensor’s transmitting surface.
  • A single unit can measure two locations. (Standard equipment: 1 sensor)
  • Using ultrasonic waves enables measurement without effects from transparency, or chromaticity, regardless of day and night.
  • The interface is measured by processing calculations based on the assumption of changes in the quality of the upper water and sediment sludge concentration, so there is no need to change the setting values or readjust them depending on the condition of the facility.
  • No driving parts in the converter and sensor, which enables stable measurement over a long period of time.

Output of Honda HL2000 Ultrasonic Level Meter

  • Alarm output
  • 4-20mA
  • RS232C

*Transmission to a PC is possible with optional communication software.

Application of Honda HL2000 Ultrasonic Level Meter

  • Interface management of settling tank at industrial wastewater treatment facility
  • Interface management for a settling tank at a sewage treatment facility

Specification of Honda HL2000 Ultrasonic Level Meter

ModelHL2000
Number of Channels2CH
Frequency400kHz
Object of measurementSludge interface
Distance measurement range0.4?10m
ResolutionMeasure1cm
Display1cm
Data updating cycle1 second
Sensor directivity angle (sound pressure half full angle)
PowerVoltageAC100?240V?±15%
Power consumption10VA
DisplayLCD display (with backlight)
OutputAlarm output2 points for each upper and lower CH
AC250V, DC30V 5A (relay contact)
4-20mA current outputResolution: 16bit, 1 point per CH
(Maximum load resistance 450?)
InterfaceRS-232C (transmission distance: within 10m)
ModelBodySensor
Ambient operating temperature-10?60?-5?60?
MaterialSteel coatingCase: PVC
Cable: PVC
StructureEquivalent to IP54Equivalent to IP68
External dimensions (WxDxHmm)280?92.5?322?80?95
Sensor cable length20m
Maximum allowable sensor cable length100m?
Wiring cable lengthNot included
Weight3.6kg2.2kg

*Please contact us when extending the sensor cable.

For More Information and Price: Honda HL2000 Ultrasonic Level Meter