Oval ALTImass Coriolis Mass Flow Meter

General

Coriolis flowmeter is a mass flowmeter to directly and continuously measure the “mass”, the only characteristic of fluid that is not affected by the change in temperature, pressure, viscosity, and density of it. Based on a unique principle utilizing Coriolis force, a wide range of mass flow rate-based systems can be configured by detecting the mass flow rate with high accuracy and sensitivity and converting it to analog or frequency output. In addition to general liquids, the flow rate of foods, chemicals, slurry, high-density gas, etc. can be measured. A major feature of the Coriolis flowmeter is a complex sensor that can measure temperature and density simultaneously with flow rate.

Oval ALTImass Coriolis Mass Flow Meter for Ultra Micro Flow Measurement high-performance type Coriolis flowmeter capable of directly measuring mass flow with high accuracy being equipped with a high-performance transmitter. Highly accurate measurement is possible even for the purpose of ultra microflow measurement and short-time filling.

Oval ALTImass Coriolis Mass Flow Meter Features

  • High accuracy
  • Setting can be changed in the field.
  • Sufficient self-diagnosis
  • Wide flow range
  • Density accuracy improved
  • Configuration excellent in cleaning
  • Large screen
  • Both temperature and density can be measured.
  • Metering of 0.2 g/min or more is available. (type/CA00A)

Oval ALTImass Coriolis Mass Flow Meter Specifications

ModelType U (High-performance model)Type SType B
(Single, straight-tube model)(Low-price, general-purpose model)
Nominal size1/4″, 10 to 250mm15, 25, 40, 50, 80mm10, 15, 25, 40, 50mm
Connection standardJIS 10, 20, 30, 40, 63KJIS 10, 20KJIS 10, 20, 30K
ASME/JPI 150, 300, 600ASME/JPI 150ASME/JPI 150, 300
Applicable fluidsLiquid, gasLiquid
Flow range0 to 2800000kg/h (16 types)0 to 108000kg/h (6 types)0 to 96000kg/h (6 types)
Operating temp. range–200 to +200°C–40 to +130°C–40 to +130°C
Maximum operating pressure (differs with connection standard)9.4MPa *1 (differs by nominal size)2.45MPa7.9MPa
Accuracy (fluid flow)±0.1% of RD (differs by nominal size)±0.2% of RD±ZS *2 (differs by nominal size)±0.2% (differs by nominal size)
Power supplyAC or DC-powered
Major part materialSUS316L, otherSUS316L
ConfigurationExplosion-proof or non-explosion-proof, IP66/67
OutputFlowrate, temperature, density (liquid), statusFlowrate, temperature, status
  • *1: Some model has a high-pressure type.
  • *2: ZS=Zero point stability error

Oval ALTImass Ultimate U-shaped Coriolis Mass flow Meter

Equipped with a sophisticated transmitter (self-diagnosis feature, large size display, and field reconfiguration capability using touch panel), “ALTImass Type U” is an all-around high-performance Coriolis flowmeter capable of mass flow measurement at a high degree of accuracy. Notable functionality in applications where measurement of extremely low flow, short-duration filling process, etc. together with routine flowrate measurements.

Oval ALTImass Type U Coriolis Mass Flow Meter
Oval ALTImass Type U Coriolis Mass Flow Meter

Top-of-the-line model in OVAL Coriolis flowmeters. The highest performance you can think of in every aspect – in accuracy, repeatability, flow range, pressure loss, and safety.

  • U-shaped flow tubes sense the Coriolis force reasonably and efficiently.
  • High-accuracy, low-pressure loss model. A 1:200 flow range is attainable.
  •  Both sensors integrated and separated transmitters are available.
  • The high-temperature sensor is best suited for flow and density measurements of fluids of max. temperature up to +350?.
  • A cryogenic sensor is applicable as an explosion-proof instrument for cryogenic fluids such as LNG

Enhanced maintenance functions

  • Zero-point adjustment function (2 methods: Status input by front key operations or adjustment button on the transmitter)
  • Error logging function
  • Clock function (Accmlated time from power on is saved in the transmitter)
  • Factory default parameter reloading function
  • Parameter backup function to the display unit

GENERAL SPECIFICATIONS

ModelCA00A, CA001, CA003, CA006, CA010, CA015, CA025, CA040, CA050, CA080, CA100, CA150, CA15H, CA200, CA20H, CA250
Nominal size1/4”, 10mm, 15mm, 25mm, 40mm, 50mm, 80mm, 100mm, 150mm, 200mm, 250mm
Process ConnectionJIS 10, 20, 30, 40, 63K RF
ASME 150, 300, 600 RF, JPI 150, 300, 600 RF
DIN PN 10, 16, 25, 40RF, Ferrule, Screw
Acceptable fluidsLiquids, Gases
Flow range0 to 2800000kg/h (16 models)
AccuracyFlowrateLiquids±0.1?RD (CA003 to CA200)
±0.1?RD±Zero stability error (CA20H to CA250, High temperature service model)
±0.2?RD (CA00A, CA001)
±0.2?RD±Zero stability error (High-pressure service model)
Gases±0.5?RD±Zero stability error
DensityLiquids±0.0005g/mL (CA003 to CA250)
±0.003g/mL (CA00A, CA001, High temperature service model)
±0.004g/mL (High-pressure service model)
Temperature range
(Differs by explosion-proof
specification)
Standard model: ?200 to ?200? (Applicable to all models)
High-temperature service model: ?40 to ?350? (CA025 to CA150)
Low temperature service model : ?200 to ?50? (CA025 to CA250) (Explosionproof model)
Max. operating pressureDepends on the flange rating
Wetted materialsSUS 316L, SUS 316L?Alloy C, Alloy CC
Explosionproof specificationTIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI
Maritime certificationDNV GL

ALTImass TypeB OVAL Coriolis Mass flowmeter

A new direction of Coriolis flowmeter presented by OVAL. Small-size, stable truly innovative product with performance.

Oval ALTImass Type B Coriolis Mass Flow Meter
Oval ALTImass Type B Coriolis Mass Flow Meter

FEATURES

  •  Low-priced, general-purpose mass flowmeter.
  • Rainbow-shaped flow tube design, facilitating self-drain, offers ease of cleaning and consistent performance.
  • A complete set of ferrule fittings are available.
  • High metering accuracy and low-pressure loss. A rangeability of 1:50 is attainable.

GENERAL SPECIFICATIONS

ModelCB006, CB010, CB015, CB025, CB040, CB050
Nominal size10mm, 15mm, 25mm, 40mm, 50mm
Process ConnectionJIS 10, 20, 30K RF
ASME 150, 300, 600 RF, JPI 150, 300, 600 RF
Ferrule
Acceptable fluidsLiquids
Flow range0 to 96000kg/h (6 models)
AccuracyFlowrate±0.2?RD
Density±0.003g/mL
Temperature range
(Differs by explosion-proof specification)
?40 to ?130?
Max. operating press.Depends on the flange rating
Wetted materialsSUS 316L
Explosionproof specificationTIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI
Maritime certificationDNV GL

ULTRAmassMK? High-pressure type Coriolis Mass Flowmeter

A high-performance Coriolis flowmeter capable of directly measuring mass flow rate with high accuracy. High-accurate measurement is also possible for the purpose of large mass flow measurement.

FEATURES

  • Exceptional accuracy (±0.2% ±zero stability error of reading for liquid service) and high sensitivity (measuring range 1 to 200).
  • Accepts both liquid and gas. Measures precisely with small pressure loss over a broad flow range.
  • Measures density and temperature accurately in addition to mass flow rate.
  • Minimum pockets for the process fluid to stand (in vertical installation) offer ease of cleaning.
  •  Lightweight and compactly built, yet exceptionally high mechanical strength. The result is the ease of handling, installation space-saving, and increased process safety.
  • Explosionproof construction permits meter installation in a hazardous location.

Sensor Unit

ModelCN010H (G)CN015H (G)
MaterialsWetted partsAlloy C-22 , Equivalent Alloy (CX2MW)
HousingSUS304
Process connectionScrew Rc3/8Screw Rc3/4
Applicable fluidLiquids and gases
Density range0 to 2 g/mL
Temp. RangeNon-explosion-proof–200 to +200°C
ExplosionproofT2: –20 to +200°C, T3: –20 to +140°C
Max. Operating pressure36MPa at normal temperature43MPa at normal temperature
Sensor housing withstanding pressure3.0MPa2.2MPa
InstallationHorizontal mount or vertical mount
Flow directionBidirectional
Explosionproof configurationIntrinsically safety explosion-proof (Ex ib IIB T2, T3)
  • ?1: Miscellaneous: For products conforming to the high-pressure gas safety regulations and consult our representative.
  • ?2: This pressure does not represent the withstanding pressure of pressure vessel ratings, but shows 1/4 the pressure of the breakdown test pressure (four-fold pressure test), accepting a deformed casing, or that in the FEM analysis, whichever is lower (safer level): it actually represents the withstanding pressure below 1/4 the breakdown pressure.
  • ?3: In applications where the fluid and atmospheric temperature exceeds 130?C, select high-temperature service meters.

ALTImass Series High-Performance Small Transmitter (Rack-Mount) MODEL: PA5K

The high-performance small transmitter is connectable to all ALTImass series sensors enabling mass flow measurement of a wide variety of fluids with high accuracy and sensitivity. It is a compact rack-mount model with a structure that is suitable for a limited space. Maintenance and inspection are also easy.

The transmitter is capable of analog output, pulse output, status input/output, and HART communication. The Modbus communication model is also available.

GENERAL PERFORMANCE

  • Compact: 48mm (width) and 165mm (depth).
  • Zero adjustments can be executed via the push-button on the transmitter, status input, or communication.
  • Input/output signals: Pulse output, analog output (two simultaneous outputs), and status input/output
  • Compatible with HART or Modbus communication
  • Excellent maintenance functions equipped with two alarm indicators (red and green)
  • Self-diagnostic function via communication (piping vibration check, error logging function, gas-mixed multiphase flow alarm (SlugAlm.), etc.)

ALTImass TypeS Coriolis Mass flow Meter

Vibration-resistant, single, straight-tube

Ideally suited for clean processes where the metered process fluid tends to build up or solidify, or where fast and positive process fluid replacement or draining of the pipeline is required.

Oval ALTImass Type S Coriolis Mass Flow Meter
Oval ALTImass Type S Coriolis Mass Flow Meter

Enhanced maintenance functions

  • Zero-point adjustment function (2 methods: Status input by front key operations or adjustment button on the transmitter)
  • Error logging function
  • Clock function (Accmlated time from power on is saved in the transmitter)
  • Factory default parameter reloading function
  • Parameter backup function to the display unit

GENERAL SPECIFICATIONS

ModelCS010, CS015, CS025, CS040, CS050, CSR50
Nominal size10mm, 15mm, 25mm, 40mm, 50mm, 80mm
Process ConnectionJIS 10, 20K RF
ASME150 RF, JPI 150 RF
Ferrule
Acceptable fluidsLiquids
Flow range0 to 91800kg/h (6 models)
Accuracy±0.15?RD±Zero stability error
Temperature range
(Differs by explosion-proof specification)
?40 to ?130?
Max. operating press.Depends on the flange rating
Wetted materialsTitanium alloy
Explosionproof specificationTIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI

More Specification:

Resource: https://www.oval.co.jp/

Other Articles:

author

Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Similar Posts