General
Coriolis flowmeter is a mass flowmeter to directly and continuously measure the “mass”, the only characteristic of fluid that is not affected by the change in temperature, pressure, viscosity, and density of it. Based on a unique principle utilizing Coriolis force, a wide range of mass flow rate-based systems can be configured by detecting the mass flow rate with high accuracy and sensitivity and converting it to analog or frequency output. In addition to general liquids, the flow rate of foods, chemicals, slurry, high-density gas, etc. can be measured. A major feature of the Coriolis flowmeter is a complex sensor that can measure temperature and density simultaneously with flow rate.
Oval ALTImass Coriolis Mass Flow Meter for Ultra Micro Flow Measurement high-performance type Coriolis flowmeter capable of directly measuring mass flow with high accuracy being equipped with a high-performance transmitter. Highly accurate measurement is possible even for the purpose of ultra microflow measurement and short-time filling.
Oval ALTImass Coriolis Mass Flow Meter Features
- High accuracy
- Setting can be changed in the field.
- Sufficient self-diagnosis
- Wide flow range
- Density accuracy improved
- Configuration excellent in cleaning
- Large screen
- Both temperature and density can be measured.
- Metering of 0.2 g/min or more is available. (type/CA00A)
Oval ALTImass Coriolis Mass Flow Meter Specifications
Model | Type U (High-performance model) | Type S | Type B |
(Single, straight-tube model) | (Low-price, general-purpose model) | ||
Nominal size | 1/4″, 10 to 250mm | 15, 25, 40, 50, 80mm | 10, 15, 25, 40, 50mm |
Connection standard | JIS 10, 20, 30, 40, 63K | JIS 10, 20K | JIS 10, 20, 30K |
ASME/JPI 150, 300, 600 | ASME/JPI 150 | ASME/JPI 150, 300 | |
Applicable fluids | Liquid, gas | Liquid | |
Flow range | 0 to 2800000kg/h (16 types) | 0 to 108000kg/h (6 types) | 0 to 96000kg/h (6 types) |
Operating temp. range | –200 to +200°C | –40 to +130°C | –40 to +130°C |
Maximum operating pressure (differs with connection standard) | 9.4MPa *1 (differs by nominal size) | 2.45MPa | 7.9MPa |
Accuracy (fluid flow) | ±0.1% of RD (differs by nominal size) | ±0.2% of RD±ZS *2 (differs by nominal size) | ±0.2% (differs by nominal size) |
Power supply | AC or DC-powered | ||
Major part material | SUS316L, other | SUS316L | |
Configuration | Explosion-proof or non-explosion-proof, IP66/67 | ||
Output | Flowrate, temperature, density (liquid), status | Flowrate, temperature, status |
- *1: Some model has a high-pressure type.
- *2: ZS=Zero point stability error
Oval ALTImass Ultimate U-shaped Coriolis Mass flow Meter
Equipped with a sophisticated transmitter (self-diagnosis feature, large size display, and field reconfiguration capability using touch panel), “ALTImass Type U” is an all-around high-performance Coriolis flowmeter capable of mass flow measurement at a high degree of accuracy. Notable functionality in applications where measurement of extremely low flow, short-duration filling process, etc. together with routine flowrate measurements.

Top-of-the-line model in OVAL Coriolis flowmeters. The highest performance you can think of in every aspect – in accuracy, repeatability, flow range, pressure loss, and safety.
- U-shaped flow tubes sense the Coriolis force reasonably and efficiently.
- High-accuracy, low-pressure loss model. A 1:200 flow range is attainable.
- Both sensors integrated and separated transmitters are available.
- The high-temperature sensor is best suited for flow and density measurements of fluids of max. temperature up to +350?.
- A cryogenic sensor is applicable as an explosion-proof instrument for cryogenic fluids such as LNG
Enhanced maintenance functions
- Zero-point adjustment function (2 methods: Status input by front key operations or adjustment button on the transmitter)
- Error logging function
- Clock function (Accmlated time from power on is saved in the transmitter)
- Factory default parameter reloading function
- Parameter backup function to the display unit
GENERAL SPECIFICATIONS
Model | CA00A, CA001, CA003, CA006, CA010, CA015, CA025, CA040, CA050, CA080, CA100, CA150, CA15H, CA200, CA20H, CA250 | ||
---|---|---|---|
Nominal size | 1/4”, 10mm, 15mm, 25mm, 40mm, 50mm, 80mm, 100mm, 150mm, 200mm, 250mm | ||
Process Connection | JIS 10, 20, 30, 40, 63K RF ASME 150, 300, 600 RF, JPI 150, 300, 600 RF DIN PN 10, 16, 25, 40RF, Ferrule, Screw | ||
Acceptable fluids | Liquids, Gases | ||
Flow range | 0 to 2800000kg/h (16 models) | ||
Accuracy | Flowrate | Liquids | ±0.1?RD (CA003 to CA200) ±0.1?RD±Zero stability error (CA20H to CA250, High temperature service model) ±0.2?RD (CA00A, CA001) ±0.2?RD±Zero stability error (High-pressure service model) |
Gases | ±0.5?RD±Zero stability error | ||
Density | Liquids | ±0.0005g/mL (CA003 to CA250) ±0.003g/mL (CA00A, CA001, High temperature service model) ±0.004g/mL (High-pressure service model) | |
Temperature range (Differs by explosion-proof specification) | Standard model: ?200 to ?200? (Applicable to all models) | ||
High-temperature service model: ?40 to ?350? (CA025 to CA150) | |||
Low temperature service model : ?200 to ?50? (CA025 to CA250) (Explosionproof model) | |||
Max. operating pressure | Depends on the flange rating | ||
Wetted materials | SUS 316L, SUS 316L?Alloy C, Alloy CC | ||
Explosionproof specification | TIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI | ||
Maritime certification | DNV GL |
ALTImass TypeB OVAL Coriolis Mass flowmeter
A new direction of Coriolis flowmeter presented by OVAL. Small-size, stable truly innovative product with performance.

FEATURES
- Low-priced, general-purpose mass flowmeter.
- Rainbow-shaped flow tube design, facilitating self-drain, offers ease of cleaning and consistent performance.
- A complete set of ferrule fittings are available.
- High metering accuracy and low-pressure loss. A rangeability of 1:50 is attainable.
GENERAL SPECIFICATIONS
Model | CB006, CB010, CB015, CB025, CB040, CB050 | ||
---|---|---|---|
Nominal size | 10mm, 15mm, 25mm, 40mm, 50mm | ||
Process Connection | JIS 10, 20, 30K RF ASME 150, 300, 600 RF, JPI 150, 300, 600 RF Ferrule | ||
Acceptable fluids | Liquids | ||
Flow range | 0 to 96000kg/h (6 models) | ||
Accuracy | Flowrate | ±0.2?RD | |
Density | ±0.003g/mL | ||
Temperature range (Differs by explosion-proof specification) | ?40 to ?130? | ||
Max. operating press. | Depends on the flange rating | ||
Wetted materials | SUS 316L | ||
Explosionproof specification | TIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI | ||
Maritime certification | DNV GL |
ULTRAmassMK? High-pressure type Coriolis Mass Flowmeter
A high-performance Coriolis flowmeter capable of directly measuring mass flow rate with high accuracy. High-accurate measurement is also possible for the purpose of large mass flow measurement.
FEATURES
- Exceptional accuracy (±0.2% ±zero stability error of reading for liquid service) and high sensitivity (measuring range 1 to 200).
- Accepts both liquid and gas. Measures precisely with small pressure loss over a broad flow range.
- Measures density and temperature accurately in addition to mass flow rate.
- Minimum pockets for the process fluid to stand (in vertical installation) offer ease of cleaning.
- Lightweight and compactly built, yet exceptionally high mechanical strength. The result is the ease of handling, installation space-saving, and increased process safety.
- Explosionproof construction permits meter installation in a hazardous location.
Sensor Unit
Model | CN010H (G) | CN015H (G) | |
---|---|---|---|
Materials | Wetted parts | Alloy C-22 , Equivalent Alloy (CX2MW) | |
Housing | SUS304 | ||
Process connection | Screw Rc3/8 | Screw Rc3/4 | |
Applicable fluid | Liquids and gases | ||
Density range | 0 to 2 g/mL | ||
Temp. Range | Non-explosion-proof | –200 to +200°C | |
Explosionproof | T2: –20 to +200°C, T3: –20 to +140°C | ||
Max. Operating pressure | 36MPa at normal temperature | 43MPa at normal temperature | |
Sensor housing withstanding pressure | 3.0MPa | 2.2MPa | |
Installation | Horizontal mount or vertical mount | ||
Flow direction | Bidirectional | ||
Explosionproof configuration | Intrinsically safety explosion-proof (Ex ib IIB T2, T3) |
- ?1: Miscellaneous: For products conforming to the high-pressure gas safety regulations and consult our representative.
- ?2: This pressure does not represent the withstanding pressure of pressure vessel ratings, but shows 1/4 the pressure of the breakdown test pressure (four-fold pressure test), accepting a deformed casing, or that in the FEM analysis, whichever is lower (safer level): it actually represents the withstanding pressure below 1/4 the breakdown pressure.
- ?3: In applications where the fluid and atmospheric temperature exceeds 130?C, select high-temperature service meters.
ALTImass Series High-Performance Small Transmitter (Rack-Mount) MODEL: PA5K
The high-performance small transmitter is connectable to all ALTImass series sensors enabling mass flow measurement of a wide variety of fluids with high accuracy and sensitivity. It is a compact rack-mount model with a structure that is suitable for a limited space. Maintenance and inspection are also easy.
The transmitter is capable of analog output, pulse output, status input/output, and HART communication. The Modbus communication model is also available.
GENERAL PERFORMANCE
- Compact: 48mm (width) and 165mm (depth).
- Zero adjustments can be executed via the push-button on the transmitter, status input, or communication.
- Input/output signals: Pulse output, analog output (two simultaneous outputs), and status input/output
- Compatible with HART or Modbus communication
- Excellent maintenance functions equipped with two alarm indicators (red and green)
- Self-diagnostic function via communication (piping vibration check, error logging function, gas-mixed multiphase flow alarm (SlugAlm.), etc.)
ALTImass TypeS Coriolis Mass flow Meter
Vibration-resistant, single, straight-tube
Ideally suited for clean processes where the metered process fluid tends to build up or solidify, or where fast and positive process fluid replacement or draining of the pipeline is required.

Enhanced maintenance functions
- Zero-point adjustment function (2 methods: Status input by front key operations or adjustment button on the transmitter)
- Error logging function
- Clock function (Accmlated time from power on is saved in the transmitter)
- Factory default parameter reloading function
- Parameter backup function to the display unit
GENERAL SPECIFICATIONS
Model | CS010, CS015, CS025, CS040, CS050, CSR50 | ||
---|---|---|---|
Nominal size | 10mm, 15mm, 25mm, 40mm, 50mm, 80mm | ||
Process Connection | JIS 10, 20K RF ASME150 RF, JPI 150 RF Ferrule | ||
Acceptable fluids | Liquids | ||
Flow range | 0 to 91800kg/h (6 models) | ||
Accuracy | ±0.15?RD±Zero stability error | ||
Temperature range (Differs by explosion-proof specification) | ?40 to ?130? | ||
Max. operating press. | Depends on the flange rating | ||
Wetted materials | Titanium alloy | ||
Explosionproof specification | TIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI |
More Specification:
- Oval-ALTImass Type U (High-Performance Model)
- Oval-ALTImass Type S (Single, straight-tube model)
- Oval-ALTImass Type B (Low-price, general-purpose model)