Nadi Series L34/L39 Closed Two Way Solenoid Valve

Description Of Nadi Series L34/L39 Closed Two Way Solenoid Valve

Nadi Series L34/L39 Closed Two Way Solenoid Valve: Nadi solenoid valves are designed according to European standards and with explosion-proof certificates according to actual “ATEX” 2014/34/UE regulations.

Nadi Series L34/L39 Closed Two Way Solenoid Valve
Nadi Series L34/L39 Closed Two Way Solenoid Valve

Design, manufacturing method, quality assurance, and tests are carried out by staff, 30 years experienced in advanced solenoid valve production, able to collaborate with customer’s technical departments in order to solve special problems, make feasibility studies for solenoid valves or duty for special applications.

Nadi Series L34/L39 Closed Two Way Solenoid Valve: Two-way direct-acting solenoid valve with spring return. Suitable for gaseous and liquid media, compatible with the (body/seals) material used, vacuum. Forged brass, nickel-plated brass, or stainless steel body. Stainless steel internal parts. Stainless steel springs. 360° degrees orientable solenoid. Mountable in any position.

Feature Of Nadi Series L34/L39 Closed Two Way Solenoid Valve

Body Material

  • Brass
  • Stainless Steel
  • **Stainless Steel

Port Size

  • 3/8? GAS
  • 1/2? GAS
  • 3/4? GAS
  • 3/8? NPT
  • 1/2? NPT
  • 3/4? NPT

Seals Materials

  • Buna N
  • FPM
  • PTFE
  • EPDM
  • HNBR (-45 deg. Celcius)

Protection Class

  • IP65

Application Of Nadi Series L34/L39 Closed Two Way Solenoid Valve

L34 Normally Closed

  • IN:In
  • OUT: Out

Funzionamento

  • Coil De-energized IN e OUT chiusi
  • Coil Energized flow from IN to OUT

Specification Of Nadi Series L34/L39 Closed Two Way Solenoid Valve

Countinuous duty glass-reinforced nylon moulded coil with electrical connection suitable for DIN-43650A plug (2 poles+ground) or “faston” wire terminal

  • Coil type: B2
  • Insulation class: F (155°C) – H (180°C) upon request.
  • Winding wire class: H (180°C)
  • Service: Continuous (S.I.) 100%ED
  • Power consumption D.C.= / A.C.~8W
    The operation in A.C. supply occurs through connector with integrated rectifier.
  • Voltage tolerance std. ±10% (others available upon request)
  • Standard voltages * 12, 24, 48, 110, 125, 220, 240
  • Electrical Insulation >1000 MOhm
  • Dielectrical strenght >2000V/1’
    * standard value in D.C. and/or A.C. 50/60Hz – other voltages available upon request.

For More Information and Price : Nadi Series L34/L39 Closed Two Way Solenoid Valve