Dinel DLS–35 Capacitive Level Sensors

Dinel DLS–35 Capacitive Level Sensors

Dinel DLS–35 Capacitive Level Sensors are designed for limit sensing of the level of liquid and bulk solids in tanks, sumps, tubes or, hoppers, silos, etc. The sensors are manufactured in several modifications of sensing electrodes (rod and rope). The electrodes can be given an insulating coating, a useful feature in case of adhesive, aggressive, or conductive media sensing. Rod electrodes are also available in a version with a reference tube for measuring fluids in tanks made from a non-conductive material.

Sensors are manufactured in the following configurations: N – for non-explosive areas, Xi – Explosion-proof – intrinsically safe for hazardous (explosive) areas, and XiM – Explosion-proof – intrinsically safe for use in mines with methane or flammable dust presence danger (see technical specifications). There are high-temperature performance NT, XiT, XiMT available. DLS is offered in variants with various types of process connections (metric and pipe thread, pressure thread NPT).

Dinel DLS–35 Capacitive Level Sensors Features

  • Direct mounting into various containers, vessels, silos, tanks, filling inlets, reservoirs, etc.
  • Outputs NPN, PNP, NAMUR (for explosive areas)
  • Sensitivity and hysteresis fluently adjustable
  • Supply voltage 7 … 36 V DC (NAMUR 8 … 12 V DC)
  • Material of housing and electrode from stainless steel
  • Process coupling – thread M27x2; M30x1.5; G3/4“ or Triclamp
  • LED state indication
  • Xi, XiT versions for usage in explosive areasor, or Xd version for usage in flamable dusts areas, or XiM, XiMT versions for mining environments with a risk of hazard by methane or coal dust

     Another Article:

Dinel DLS–35 Capacitive Level Sensors Specification

Power consumption (variant DLS-35N(T))  7 … 34 V DC
Power consumption (variant DLS-35N(T)) max. 5 mA
Max. switching current (NPN, PNP output) 300 mA
Residual voltage – ON state max. 1,5 V
Input resistance / electric strength  1 MΩ / 200 V DC
Coupling capacity (housing – power)/ dielectric strength  50 nF / 350 V AC
Coupling capacity (electrode – power) / dielectric strength 47 nF / 350 V AC
Protection class
type DLS-35_-_ _-C-_-_ IP67
type DLS-35_-_ _-A(B,V,H)-_-_ IP68
Cable (versions with cable outlets) PVC 3 x 0,5 mm2
Weight (excl. electrode and cable)
variant N cca 0,3 kg
variant NT cca 0,6 kg
Power supply voltage  8 … 9 V DC
Current consumption (disconnected/ connected) – NAMUR  ≤ 1 mA / ≥ 2,2 mA
Limit values Ui = 12 V DC; Ii = 15 mA; Pi = 45 mW; Ci = 15 nF; Li = 10 μH
Reference value LC for the parameters of the used cable typic C < 150 pF/m
typic L < 0,8 μH /m

Download Catalog: Dinel DLS–35 Capacitive Level Sensors

Ref: Dinel.cz

Share
Dinel DLS–35 Capacitive level sensors

Dinel DLS–35 Capacitive level sensors

Capacitive level sensors DLS® are designed for limit sensing of the level of liquid and bulk solids in tanks, sumps, tubes or, hoppers, silos, etc. The sensors are manufactured in several modifications of sensing electrodes (rod and rope). The electrodes can be given an insulating coating, a useful feature in case of adhesive, aggressive, or conductive media sensing. Rod electrodes are also available in a version with a reference tube for measuring fluids in tanks made from a non-conductive material.

Sensors are manufactured in the following configurations: N – for non-explosive areas, Xi – Explosion-proof – intrinsically safe for hazardous (explosive) areas and XiM – Explosion-proof – intrinsically safe for use in mines with methane or flammable dust presence danger (see technical specifications). There are high temperature performance NT, XiT, XiMT available. DLS is offered in variants with various types of process connections (metric and pipe thread, pressure thread NPT).

Features:

  • Direct mounting into various containers, silos, vessels, tanks, filling inlets, reservoirs, etc.
  • Increased resistance to electromagnetic interference
  • Simply sensitivity setting through magnetic pen
  • Mode for quick setting of the sensor without the presence of medium
  • LED state and function indication
  • Wide choice of electric connection via connectors, cable glands, or protective conductor
  • The material of housing and electrode from stainless steel
  • High stability at high sensitivity (can be used for material with Ɛr ≥ 1,3)
  • Xi, XiT versions for usage in explosive areas, or XiM, XiMT versions for mining environments with a risk of hazard by methane or coal dust

Specification

Basic technical data
Power consumption (variant DLS-35N(T))  7 … 34 V DC
Power consumption (variant DLS-35N(T))  max. 5 mA
Max. switching current (NPN, PNP output)  300 mA
Residual voltage – ON state  max. 1,5 V
Input resistance / electric strength  1 MΩ / 200 V DC
Coupling capacity (housing – power) / dielectric strength  50 nF / 350 V AC
Coupling capacity (electrode – power) / dielectric strength 47 nF / 350 V AC
Protection class  type DLS-35_-_ _-C-_-_ IP67
type DLS-35_-_ _-A(B,V,H)-_-_ IP68
Cable (versions with cable outlets)  PVC 3 x 0,5 mm2
Weight (excl. electrode and cable) variant N cca 0,3 kg
variant NT cca 0,6 kg

 

Electrical parameters (variant Xi, XiT, XiM, XiMT)
Power supply voltage  8 … 9 V DC
Current consumption (disconnected/ connected) – NAMUR  ≤ 1 mA / ≥ 2,2 mA
Limit values  Ui = 12 V DC; Ii = 15 mA; Pi = 45 mW; Ci = 15 nF; Li = 10 μH
Reference value LC for the parameters of the used cable  typic C < 150 pF/m
typic L < 0,8 μH /m