Flush-Mounted Pressure Transmitter Hengesbach TCF050D

General

The Hengesbach TCF050D pressure transmitter is suitable for measuring pressure in applications with pulsing pressure and the danger of pressure shocks and cavitation e.g. in barrel filling systems. The piezoresistive measurement cells with the ceramic membrane are designed for measurement ranges from 0…1 bar to 0…100bar.

The flush-mounted process connections with G1/2“ / M22x1.5 are equipped with the Hengesbach TCF050D pressure transmitter with diaphragm seals and stainless steel membrane. These are ideal for flush-mounting in small pipe nominal widths. High-temperature versions for constant temperatures of up to 200°C are also available. The stainless steel field housing in IP 67 and IP 69K is resistant to all common cleaning procedures.

All  Hengesbach TCF050D series pressure transmitters are equipped with a micro-processor controlled electronics system and an accuracy of ≤ ± 0.4% FS. They are parametrized with a simple and user-friendly operating concept via 2 keys and a multi-color status LED. They are highly suited for applications with basic requirements of functionality and exactness.

Features: Hengesbach TCF050D pressure transmitter

  • overload-proof design especially for use with small pipe widths such as KEG systems
  • output signal 4…20mA, Turn Down 4
  • accuracy ≤ ± 0,4%FS
  • standard process connections for industrial applications
  • simple data metering via 2-key concept and multiple-color status LED
  • simple calibration, even without disconnection of the transmitter, through a switchable power supply plant/calibrator supply
  • for pressure measurement with basic requirements
  • stainless-steel housings in the protection class IP 67 and IP 69K

Specification:

General details
Device type/measuring principleTCF050D: piezoresistive
Input
Measuring rangesTCF050D
Standard nominal measuring range [bar]RelativeOPAbsoluteOPRelativeOPAbsoluteOP
OP = overload protection [bar]-1/0 to 120 to 12-1/0 to 20400 to 2040
Special measuring ranges are available on request.-1/0 to 240 to 24-1/0 to 501000 to 50100
-1/0 to 5100 to 5100 to 100200
All measurement cells are vacuum safe
-1/0 to 10200 to 10200 to 200
Recommended minimum temperature range2.5 bar
Setting the measuring rangesvia the 2 keys within the transmitter
Setting rangesMeasuring range beginzero:0 to 75%of the sensor’s nominal measuring span
Measuring spanspan:25 to 100%of the sensor’s nominal measuring span
Burst pressure DIN16086>= 4-fold nominal measuring range
Output
Output signal2-wire:   4 to 20mA with a test circuit connection in the device
Fault signal22mA
Current limitation3.8mA and 21mA (normal operation, cannot be set)
Measuring accuracy
Reference conditionsacc. to DIN IEC 770
Linearity, hysteresis and repeatability acc. to the limit point method DIN IEC 770≤ ± 0.4% of the sensor nominal measuring range
Activation time< 2 s (The device will carry out a self-test.)
Setting time< 1s
Long-time drift≤ 0.2% of the span per year
Thermal hysteresis≤ ± 0.2% from sensor nominal measuring range / 10K (-20…+80°C) from 4bar
Conditions of use
Installation position/calibration positionAny position/standing vertically
Medium temperatureG2 / G6:  -40…+125°C (140°C for max. an hour)
G7 / M9:  -40…+200°C (high-temperature version)
Ambient storage temperature-40…+85°C (below -20 °C danger of cable breakage)
Protection class acc. to EN60529IP 67 and IP 69K
Electromagnetic compatibilityacc.to EN 61326-1
Construction
Electrical connection– Standard:cable screw connection M16x1.5, nickel-plated brass (stainless steel available on request)
– Optional:  round plug-in connector M12x1, nickel-plated brass (stainless steel available on request)
– Optional:  angle plug acc. to EN 175301-803
– Optional:  reference cable
Process connection– All standard flush-mounted process connections and those commonly used by the manufacturer
– Membrane, flush-welded on the front, CrNiSt, other materials available on request
– EPDM process seal (with a G6 process connection)
– FPM process seal (with G7 and M9 process connections)
Construction
Materials– Field housing / lid:CrNiSt 1.4301 (304)
– Electronics cast:Silgel
– Housing seal:FPM (Viton®)
– Pressure compensation element:Polyamide
– Process connection / connection adapter:CrNiSt 1.4404 (304)
– Process membrane:Ceramic (96% Al203) / CrNiSt 1,4435/1,4404 (316L)
– Reference cable, 5-wire with reference tube:  PUR (recommended: 80 m maximum)
Filling fluidSilicon oil (FDA)
Display and operation
DisplayMultiple-colour status LED
Operation2-key concept
Auxiliary energy resources
Power supply / burden12…30V DC, max. burden: (Vsupply – 12V) / 22mA
Accessories series 050D
CertificatesCalibration certificate
Declaration of conformity
Material certificate acc. to EN 10204


Download Data Sheet: Flush-Mounted Pressure Transmitter TCF050D

Ref: Hengesbach.com