Gastec CG-1 system can simply, quickly, and simultaneously measure 4 kinds of harmful contaminants (CO, CO2, Water vapour, and Oil mist)
contained in compressed breathing air (cylinder or compressor).
- Accurate simultaneous measurement of 4 impurities (CO, CO2, Water vapour, and Oil mist) in compressed breathing air is achieved by simply connecting the device to a cylinder or compressor.
- Easy measurement without any electricity or power source.
- Handy carrying case for storage and easy portability.

Specification of Gastec CG-1 Compressed Breathing Air Measurement Kit
Standard accessories | Measuring device,Rubber shroud,GASTEC Tubes(1A,2A,6A,109AD), Stopwatch, Tube tip holder, Carrying case, Deep socket |
Detector Tube
Substance to be measured | Tube no. & name | Measuring range (ppm) | Scale range (ppm) | No. of tests per box | Detector tube type | Notes | |
Carbon dioxide | 2A | Carbon dioxide | 250-3000 | 250-3000 | 10 | Airtec | |
Carbon monoxide | 1A | Carbon monoxide | 5-50 | 5-50 | 10 | Airtec | |
Oil mist | 109AD | Oil mist | 0.1-5.0mg/m3 | 0.2-5.0mg/m3 | 10 | Airtec | |
Water vapour | 6A | Water vapour | 10-80mg/m3 | 10-80mg/m3 | 10 | Airtec |
Specification of Airtec Tube
Airtc Tube | Measuring range | Flow rate | Sampling time | |
Carbon Monixide | 1A | 5-50 ppm | 100 mL/min | 5 minutes |
Carbon Dioxide | 2A | 250-3000 ppm | 190 mL/min | 5 minutes |
Water Vapour | 6A | 20-80 mg/m3 | 120 mL/min | 5 minutes |
Oil Mist | 109AD | 0.2-5.0 mg/m3 | 3000 mL/min | 10 minutes |
0.1-0.2 mg/m3 | 3000 mL/min | 20 minutes |
For More Information and Price: Gastec CG-1 Compressed Breathing Air Measurement Kit
Read More Articles:
- Neodyn 182P NEMA 4X, 7, 9 and 13 Vacuum Switch
- Neodyn 182P NEMA 4 and 13 Vacuum Switch
- Neodyn 200P NEMA 4 and 13 Pressure Switch
- Flowma SMP858-TST-H Gauge Pressure Transmitter
- Shanceng Gas Meter G2.5
You must be logged in to post a comment.