GASTECP-5 Permeation Tube Sulphur Dioxide
Although technology is always evolving, one demand for our products never changes: the demand for customer safety. Whenever we contribute to customer safety, we are presented with an opportunity to develop further. GASTEC holds this corporate creed of safety and development in high esteem, as it strives to grow while always putting customer safety first.

Gastec P-5 Permeation Tube Sulphur DioxideGastec P-5 Permeation Tube Sulphur Dioxide Generating calibration gas with a permeation tube. Concentration range 0.04 – 3.6 ppm.
Generating Calibration gas with a permeation tube
A permeation tube is a fluoro resin tube that contains high-grade liquefied gas. When the tube is exposed to a certain temperature, liquefied gas penetrates the tube wall by osmosis in time increments enabling a specific quantity of gas to be retained in the tube. Consequently, a carrier gas flowing at a constant speed (for calibration purposes) can be continuously generated by keeping the tube at a fixed temperature and infusing a constant quantity of dilution gas. This method is highly reliable because the concentration of the calibration gas is determined by calculating the decrease in weight of the permeation tube and the quantity of dilution gas. This dynamic method also enables highly reactive gases such as chlorine, hydrogen sulphide, or ammonia to be generated. As shown in the table below, there are many different kinds of permeation tubes and they are widely used because they can provide a stable supply of calibration gas.
Here are the features and specifications for the Gastec P-5 Permeation Tube (Sulphur Dioxide).
Product Overview
The Gastec P-5 Permeation Tube is a specialized tool used to generate a continuous, stable, and precise concentration of Sulphur Dioxide ($SO_2$) gas for calibration purposes. It is designed to be used with a gas generator system (permeater), such as the Gastec PD-1C.
Features of Gastec P-5 Permeation Tube Sulphur Dioxide
High Purity: Contains high-grade liquefied Sulphur Dioxide gas within a fluororesin tube.
Stable Generation: When kept at a constant temperature, the gas permeates through the tube wall at a stable rate, allowing for the continuous generation of calibration gas.
High Reliability: The concentration is determined by a physical principle (weight loss over time), making it a primary standard for calibration.
Adjustable Concentration: The final gas concentration can be adjusted by changing the temperature setting of the permeater or the flow rate of the dilution gas.
Specifications of Gastec P-5 Permeation Tube Sulphur Dioxide
| Specification | Detail |
| Model Number | P-5 |
| Target Gas | Sulphur Dioxide ($SO_2$) |
| Concentration Range | 0.1 – 7.2 ppm* |
| Tube Material | Fluororesin (FEP) |
| Method | Permeation Tube Method |
| Boiling Point Range | -60°C to +30°C (characteristic of gas inside) |
| Working Temperature | Typically set at 30°C, 35°C, or 50°C (using a Permeater) |
| Compatible Equipment | Gastec Permeater (e.g., PD-1C, PD-1B) |
For more information and price: Gastec P-5 Permeation Tube Sulphur Dioxide
Read More Articles:
- Bamo BES 680 Floor Leak Detection
- Pepperl+Fuchs LA28/LK28-FC-Z/31/116 Fire protection thru-beam sensor
- Pepperl+Fuchs GD18/GV18/73/120 Thru beam sensor
- Pepperl+Fuchs BB10-P-F1/25/33/35/103/115-7m
- Pepperl+Fuchs Thru Beam Sensors