Description of Gastec TG-1 Toxic Gas Detection Kit
The primary step towards being able to prevent hazardous gas generation at the workplace, as part of occupational hygiene and pollution control, is to acquire accurate data regarding the emitted gas types and their concentration levels. Our hazardous gas detection kit consists of 12 detector tubes.
- There is no need to possess special technology, knowledge, or skills.
- Operation is simple. There is no need to carry out electrical or mechanical operations.
- One measurement takes place in 1-4 minutes, enabling the product to function rapidly in an emergency.
- There is no need for a power supply, so you can carry out measurement in any location whatever and judge the results on the spot.
- Both the initial cost and running costs are low, and maintenance is unnecessary.

Detector Tube
The substance to be measured | Tube no. & name | Measuring range (ppm) | Scale range (ppm) | No. of tests per box | Detector tube type | Notes | |
Acetone | 151L | Acetone | 50-12000 | 50-4000 | 10 | Short-term measurement | |
Ammonia | 3La | Ammonia | 2.5-220 | 5-100 | 10 | Short-term measurement | |
Bromine | 8La | Chlorine | 0.05-0.8 | 10 | Short-term measurement | ||
Carbon monoxide | 1L | Carbon monoxide | 2.5-2000 | (25)-1000 | 10 | Short-term measurement | |
Ethyl acetate | 141 | Ethyl acetate | 0.1-1.5% | 0.1-1.5% | 10 | Short-term measurement | |
Hydrogen chloride | 14L | Hydrogen chloride | 0.2-76 | 1-20 | 10 | Short-term measurement | |
Hydrogen cyanide | 12L | Hydrogen cyanide | 0.5-150 | 2.5-60 | 10 | Short-term measurement | |
Hydrogen sulphide | 4LL | Hydrogen sulphide | 0.25-120 | (2.5)-60 | 10 | Short-term measurement | For preventing oxygen depletion |
Methanol | 111L | Methanol | 20-1000 | 40-1000 | 10 | Short-term measurement | |
Qualitative analysis | 107 | Polytec tube-1 | Qualitative analysis | Qualitative analysis | 10 | Polytec | For firefighting Unknown Gases |
Stoddard solvent | 128 | Stoddard solvent | 50-8000mg/m3 | 50-8000mg/m3 | 10 | Short-term measurement | |
1,1,1-Trichloroethane | 135 | 1,1,1-Trichloroethane(Methyl chloroform) | 100-2000 | 100-500 | 5 | Short-term measurement |
How to Use Gastec TG-1 Toxic Gas Detection Kit
- Airstream checks using a smoke tester.
- Commencement of measurement using detector tube polytech No. 107 for qualitative measurement of an unknown gas.
- Progressive measurement using a detector tube, according to the judgment of a matrix diagram.
- Judgment (gas name check, non-existent, below the detection limit).
For more details information and price, please click this link: Gastec TG-1 Toxic Gas Detection Kit
Read More Articles:
- Pressure and Level Transmitters Keramess KS 050D Series Hengesbach
- Flush-Mounted Pressure Transmitter TCS Type Hengesbach
- Pressure Transducer DMU 100 Series Hengesbach
- Hengesbach Pressure Transmitter DME 11 Series
- Delta Mobrey S21 Pressure Switch
You must be logged in to post a comment.