Trafag NAT 8252 Industrial Pressure Transmitter

They are available in many different designs to suit pressure and electrical connections, measuring procedures, electrical output signals, and certifications (CE, EX, rail, and ship).

About Pressure Transmitters

Pressure transmitters are electronic pressure gauges and are used to measure and monitor pressure. The term pressure transmitter is also often used for pressure transducers or pressure sensors. However, this is not a synonym, since the term pressure sensor in the narrower sense only describes a part of the pressure transmitter.

Trafag NAT 8252 Industrial Pressure Transmitter
Trafag NAT 8252 Industrial Pressure Transmitter

Description of Trafag NAT 8252 Industrial Pressure Transmitter

The industrial pressure transmitter NAT 8252 features an exceptionally long-term stable thin-film-on-steel sensor cell with triple (optionally 5-fold) overpressure safety. Optionally, the NAT 8252 is available as a pressure switch with 1 or 2 switching outputs. The robust design and the wide temperature range from -40°C to +125°C qualify the NAT 8252 as the ideal solution for a wide range of demanding applications.

Main Features of NAT 8252 Industrial Pressure Transmitter

  • Smallest design
  • Completely welded steel sensor system without additional seals
  • Excellent long-term stability
  • Optional: 5-fold overpressure resistance
  • Optional: Switching output 1 or 2 PNP

Technical Data of NAT 8252

More Information
Product code8252
NameNAT
DesignationIndustrial Pressure Transmitter
Product categoryPressure transmitters
Measuring range0 … 2.5 a 0 … 700 bar 0 … 30 a 0 … 10000 psi
Measuring principleThin-film-on-steel
ApplicationsHVAC
Hydraulics
Machine tools
Process technology
Refrigeration
Water treatment
Accuracy @ 25°C typ.± 0.5 % FS typ.
Output signal4 … 20 mA, 0 … 5 VDC, 1 … 5 VDC, 1 … 6 VDC, 0 … 10 VDC and more, 0.5 … 4.5 VDC ratiometric, Switching output: 1 or 2 PNP
Electrical connectionsIndustrial standard, contact distance 9.4 mm; M12x1; MIL-C 26482; Deutsch DT04-3P/4P; Cable
Pressure connectionsG1/4″ m; G1/4″ m (Manometer); G1/4″ m with integrated damping; G1/8″ m, DIN3852-E; 1/4″NPT m; 1/4″NPT f; 1/8″NPT m; 7/16″-20UNF f, SAE J512; 7/16″-20UNF m, SAE4 (J1926); 7/16″-20UNF m, DIN3866; 9/16″-18UNF m, SAE6 (J1926); R1/4″ m, DIN3858; R1/4″ m, DIN29
Media temperature–40°C … +125°C
Ambient temperature–40°C … +125°C (Cable PVC 22: -5°C … +60°C) (Cable PUR 24: -40°C … +70°C) (Cable Radox Tenuis 88: -40°C … +100°C)