General Description
Wenglor OCP352H0180 sensors work with a high-resolution CMOS line and DSP technology and determine distance using angular measurement. As a result, material, color, and brightness-related measurement differences are virtually eliminated. The integrated analog output can be configured for voltage 0…10 V (10…0 V) or current 4…20 mA (20…4 mA).
- Linearity: 0,15 % (resolution-mode)
- High resolution: 50 µm (resolution-mode)
- Zoom function
- Measured value independent of material, color, and brightness
Wenglor OCP352H0180 Specification
Optical Data
Working Range | 50…350 mm |
Measuring Range | 300 mm |
Resolution | 50 µm |
Resolution (Speed-Mode) | 80 µm |
Linearity | 0,15% |
Linearity (Speed-Mode) | 0,20% |
Light Source | Laser (red) |
Wavelength | 660 nm |
Service Life (T = +25 °C) | 100000 h |
Laser Class (EN 60825-1) | 1 |
Max. Ambient Light | 10000 Lux |
Light Spot Diameter | see Table 1 |
Electrical Data
Supply Voltage | 18…30 V DC |
Current Consumption (Ub = 24 V) | < 80 mA |
Measuring Rate | 500 /s |
Measuring Rate (Resolution-Mode) | 250 /s |
Response Time | < 2000 µs |
Response Time (Resolution Mode) | < 4000 µs |
Temperature Drift | < 25 µm/K |
Temperature Range | -25…50 °C |
Analog Output | 0…10 V/4…20 mA |
Load Current Voltage Output | < 1 mA |
Current Output Load Resistance | < 500 Ohm |
Interface | RS-232 |
Baud Rate | 38400 Bd |
Protection Class | III |
FDA Accession Number | 1120723-000 |
Wenglor OCP352H0180 Mechanical Data
Setting Method | Teach-In |
Housing Material | Plastic |
Degree of Protection | IP67 |
Connection | M12 × 1; 8-pin |
Output
Error Output | yes |
Analog Output | yes |
RS-232 Interface | yes |
Datasheet: Wenglor OCP352H0180 Photoelectronic sensor
Reference: wenglor.com
Other Articles
- Wenglor Retro K1R87PCT2 Reflex Sensor for Clear Glass Recognation
- Wenglor OCP352H0180 Photoelectronic Sensor
- Wenglor HT80PA3 Reflex Sensor
- WENGLOR SENSOR
- Industrial Sensor Wenglor