Kofloc DF-250C Series Digital Mass Flow Meter is a high-performance digital mass flow controller with ?1 sec response less than 50SLM specification. The series offers a large flow rate line-up up to 300SLM.

Kofloc DF-250C Series Feature

  • Standard gases are calibrated with actual gas
  • ~50SLM model offers a fast response of ?1 sec
  • 10sccm ~ 300SLM flow range line-up
  • Communications functions installed as a standard feature(RS485)
  • RoHS/CE Standard compliant

Specification

Sensor typeThermal sensor
Valve typeNormally closed proportional solenoid valve
Applicable gases*1N2, Air, H2, He, Ar, O2, CO2, etc.?Air, N2
(Gases not specifically mentioned here are subject
to calibration for N2 equivalent.)
Flow range*210 SCCM to 10 SLM20 to 50 SLM100, 150 SLM200, 300 SLM
(20 to 30 SLM for CO2)
Control range2 to 100% (F.S.)5 to 100% (F.S.)
Response*3Total flow rate control range ? 1 sec (within ±2% F.S.)?? 1.5 sec / ? 3 sec less than 10%?? 2 sec (within ±2% F.S.)
(within ±2% F.S.)
Accuracy*4±1.0% F.S.±2.0% F.S
Repeatability±0.25%F.S.±0.5%F.S.
Operating differential50 to 300 kPa100 to 300 kPa150 to 350 kPa200 SLM: 200 to 350 kPa
pressure*5(100 to 300 kPa for Ar and CO2)(150 to 300 kPa for Ar and CO2)300 SLM: 250 to 350 kPa
Inlet maximum pressure500kPa?G?
Proof pressure980kPa?G?
External leak rate?1.0 x 10-8 Pa·m3/sec (He)?1.0 x 10-7 Pa·m3/sec (He)
Temperature5 to 50?
15 to 35?
-10 to 60?
Allowable operating humidity10 to 90% RH (without dew condensation)
Materials of gas contact partSUS316, SUS316L, magnetic stainless steel, Ni, PTFE, PCTFE, and FKM
Electrical connectionD-sub 9-pin, KFC standard (SEMI standard compliant), RJ-45 modular jacks (two)D-sub 9-pin ,
HR-10A (two)
Flow rate setting signal0 to 5 V DC (input impedance: approx. 1 M?)
Flow rate output signal0 to 5 V DC (load resistance 10 k?)
Digital communicationAddress setting with RS485 rotary switch: up to 99 devices (9600 bps)
Required power supply (DC)+15 V DC (±5%) : 150 mA+15 V DC (±5%) : 150 mA24 V DC (±10%) : 450 mA
-15 V DC (±5%) : 150 mA-15 V DC (±5%) : 250 mA
Joint*61/4 F900 (standard), 1/4 UJR, Rc 1/41/2 SW (standard), 3/4 SW
Mounting postureHorizontal installation recommended.
Weight*7Approx. 850 gApprox. 1000 gApprox. 2250 gApprox. 3500 g
  • The gases must be dry and clean, free of corrosive components and foreign matter such as dust and mist.
  • Dedicated software is available to change gases or change the actual full scale (F.S.) within the range of 30 to 100% (30 to 80% for CO2 only) of the specified full scale.
  • The flow rate calibration units SCCM and SLM indicate a mass flow rate converted to a volume flow rate in cc/min and L/min at 0°C and 1 atm.
  • Guarantee for calibration gas: N2.
  • Accuracy for calibration gas: N2, flow range (max. full scale).
  • The operating differential pressure may differ depending on specifications.
  • Contact us for any other joints.