Flocorp Tracer 1000 LTT1-2G 2nd Generation Radar Level Transmitter

Flocorp Tracer 1000 LTT1-2G 2nd Generation Radar Level Transmitter provides continuous level measurement in liquids, solids, and slurries. This innovative device has almost no installation restrictions in tanks, silo, and bins up to 80 feet. The Tracer 1000™ 2G has a fully isolated 4-20 mA output that can be scaled for tank level or distance. The unit requires 18 to 30 VDC power.

The 4-wire device comes standard with an RS-485 COMMS output that can be connected to the Tracer Talker™ software for custom configurations and detailed level processing analysis. The Tracer 1000™ 2G ships pre-calibrated precisely for the customer’s application for quick installation and setup. If adjustment is needed in the field the RS485 Communication Tool and Tracer Talker™ software is recommended.

TDR technology is not affected by pressure, vacuum, temperature, viscosity, foam, or dust. Changes in the dielectric constant or coating of the probe do not affect the level measurement due to the dynamic sensing technology programmed into the artificial intelligence of the Tracer 1000™ 2G GWR level transmitter

Flocorp Tracer 1000 LTT1-2G Features and Benefits

  • Revolutionary TDR Technology
  • Auto Calibration to any dielectric
  • Precise continuous level measurement
  • Measures liquids, slurries, and solids
  • Highly robust measurement due to the 4-wire design and innovative signal analysis and constant disturbance signal suppression
  • Measures up to 80 feet
  • Pre-calibrated from factory for easy installation
  • High-temperature applications
  • Programmable fail-safe mode
  • RS485 Communication Tool and Software are available for purchase if calibration adjustments are required

Primary Area of Applications

  • Chemical / Petrochemicals
  • Energy
  • Food & Beverages
  • Plastic Pellets
  • Minerals & Mining
  • Oil & Gas
  • Pharmaceutical
  • Pulp & Paper
  • Wastewater
  • Transport
  • Overflow Protection
  • Asphalt Blending Tanks
  • Alum and Wax Tanks
  • Sand and Gravel
  • Primary and Secondary Sludge Clarifiers
  • Fresh Cooking Oil
  • Used Cooking Oil

Flocorp Tracer 1000 LTT1-2G Specification

Signal OutputIsolated 4-20 mA (750 ohms @24Vdc
User Voltage Supply, 250 ohms internally driven)
Fail-Safe Output3.8 mA, 4 mA, Last Known, 20 mA, 20.2 mA
Operating Voltage12-30 Vdc (residual ripple no greater than 100 mV)
Power Consumption<3W @ 24 Vdc
CommunicationsRS485 Modbus
(RS485 activation required Tracer Talker™ Communication Software and Tool).
Signal WiringRecommended Signal Output and Communications Output is twisted shielded pairs, 20-18 AWG
Measurement Range1.2’ to 80’ with minimum dielectric
constant of 0.3
Resolution0.0008″
Accuracy+/- 0.039” ( 1 mm) or 0.02% of the measured distance, whichever is greatest.
Update Interval100 samples/sec/updated <100 millisec.
Ambient Temp. Effect+/- 0.005”/K of a measured value
Repeatability+/- 0.02” (0.5mm)
Electronics: -40º to 158ºF (-40 to 70ºC) Process/Probe: -40º to 398ºF standard
Maximum Operating Temperature-50º to 593ºF with Temp. Extender Option
Maximum Operating Pressure-14.50 PSI to 580 PSI
Process Connection/ TypeStandard: 1.50″ MNPT
Option:      1.50″ ANSI 150lb. Flange
Probe Type/DiameterRod Probe: 316 Stainless Steel, 0.25″ diameter
Wire Cable Probe: 316 Stainless Steel, 0.195″ diameter Weighted Assembly: 0.75″ diameter
Tensile Load4,270 lbs
EnclosureNEMA 6: Coated Epoxy Aluminum with IP67 Sealing
Cable Entries(2) 1/2″ NPT Conduit Entries
A22 ATEX Grp II Cat 3 GD T75°C IP67
ApprovalsTamb -40°C to 65°C

Ref: Flo-corp.com

Download Datasheet: Tracer 1000™ LTT1-2G 2nd Generation Radar Level Transmitter Flocorp